AC
Ambiente Construído
Ambiente Construído
1415-8876
1678-8621
Associação Nacional de Tecnologia do Ambiente Construído - ANTAC
Abstract
In the current context, tall reinforced concrete buildings are becoming commonplace, with legislation imposing mandatory consideration of fire action in their designs. Supporting high temperature evaluations and responsive to demands for a broader spectrum of solutions, a computer programme is presented for practical calculations of beam fire resistance times, with results for over 2300 combinations of cross-sections and reinforcement arrangements. Called TRFVIG, it applies an alternative design method that complies with standard guidelines, grounded on simulations of thermo-structural behaviours by finite elements. With no ceiling temperatures established for reinforcements and based solely on the balance of forces, examples indicate it could produce results that are more cost-effective than the tabular method used by the Brazilian standard. Developed as a stand-alone application compatible with Windows 7 or higher, its intuitive graphical interface is easy-to-use. Six beam characteristics are selected, with the only data requiring calculation being the ratio between bending moments as determined by simple equations, with no need for thermal analysis. An unprecedented, free of charge alternative tool for designers, it feasibly boosts computer technology use for Fire Safety, driving advances in the construction of buildings planned to adequately withstand events of this type.
Introdução
No Brasil, as exigências de segurança contra incêndio das edificações são definidas em legislação estadual. A legislação de diversos estados brasileiros exige que as estruturas das edificações sejam verificadas para a situação de incêndio. Onde não há essa exigência explícita, aplica-se o Código de Defesa do Consumidor (Lei Brasileira n˚ 8.078/1990) (Brasil, 1990), que proíbe a comercialização de produtos ou serviços em desacordo com normas expedidas pelos órgãos oficiais competentes ou, se essas normas específicas não existirem, pela Associação Brasileira de Normas Técnicas (ABNT). Portanto, na ausência de lei específica, vale a norma NBR 14432 (ABNT, 2001).
Note-se que o projeto de segurança contra incêndio é exigido pela legislação brasileira para estruturas de grande porte, com alta densidade de pessoas, de difícil desocupação e/ou com maior risco de incêndio, em que o fogo pode gerar grandes perdas e comprometer a segurança dos ocupantes do local. Edifícios de baixo risco à vida, que compreendem edifícios de fácil desocupação, tais como construções de pequeno porte, edificações horizontalizadas, edifícios industriais, galpões ou depósitos, podem ser dispensados da verificação da segurança estrutural, exceto quando há interesse em proteção patrimonial. Esses edifícios isentos dos requisitos de resistência ao fogo são identificados no anexo A da NBR 14432 (ABNT, 2001) e nas Instruções Técnicas (ITs) dos Corpos de Bombeiros locais, que têm precedência em relação à ABNT. Mais informações são apresentadas em Silva (2012, 2014).
Os objetivos do projeto de segurança contra incêndio consistem em:
minimizar os riscos de colapso, a fim de garantir que as estruturas resistam por tempo suficiente para que as pessoas abandonem em segurança o espaço do sinistro;
salvaguardar a equipe de combate;
limitar os danos em propriedades próximas à zona comprometida; e
reduzir perdas patrimoniais da sociedade.
Portanto, a calculadora para determinação da resistência ao fogo de vigas de concreto armado desenvolvida nesta pesquisa traz consigo a contribuição em um tema relevante e necessário, tanto do ponto de vista técnico quanto social, pois representa uma ferramenta que auxilia a projetar estruturas para a situação de incêndio.
Com linguagem simples e fácil aplicação, a calculadora efetua o dimensionamento ao fogo das vigas a partir de um método que envolve, sobretudo, dados conhecidos pelos projetistas. Este artigo apresenta as bases do estudo que comprovam sua precisão, os processos que nortearam seu desenvolvimento, além da abordagem de seus resultados.
A calculadora denominada TRFVIG (acrônimo para Tempo de Resistência ao Fogo de VIGas de concreto armado) foi criada num contexto contemporâneo, onde é crescente o desenvolvimento de ferramentas computacionais que simplifiquem e aprimorem a prática de projetos, e adere ao movimento que busca democratizar o dimensionamento ao fogo, tornando soluções mais precisas e econômicas acessíveis. Nesse aspecto, a tecnologia pode auxiliar na integração dos escritórios de engenharia e arquitetura à execução de projetos de estruturas sob temperaturas elevadas.
A Engenharia de Segurança Contra Incêndio é uma área relativamente recente e muitos profissionais ainda não estão totalmente familiarizados com a inclusão de exigências relacionadas ao fogo na etapa de projeto da estrutura. Além disso, as soluções de métodos convencionais podem ser insuficientes, sendo habitual delegar o projeto de incêndio a especialistas. Alguns países estão mais avançados, porém, a quantidade desses profissionais ainda é limitada, por exemplo, no Brasil.
Portanto, visa-se incentivar uma participação maior dos escritórios de projeto, ao proporcionar uma ferramenta mais eficiente, que demanda conhecimento mínimo de aspectos teóricos do assunto. Sua disseminação pretende iniciar uma tendência de criação de soluções computacionais que possam auxiliar a fortalecer essa área, resultando no avanço de edificações construídas para resistirem com eficácia a eventos dessa natureza.
A ferramenta é útil a engenheiros civis e arquitetos que atuam em escritórios de projeto estrutural e na área acadêmica. Destaca-se que a Lei Brasileira n˚ 13.425/2017 (Brasil, 2017), conhecida como Lei Kiss, exige que tópicos de Segurança Contra Incêndio sejam ministrados nos cursos de graduação em Engenharia e Arquitetura.
A relevância da calculadora foi reconhecida pelo Instituto Brasileiro do Concreto (IBRACON) e pela Associação Brasileira de Engenharia e Consultoria Estrutural (ABECE), que a fornecem como contribuição técnico-científica aos seus membros; pela Universidade de São Paulo (USP), que se tornou titular dos direitos de propriedade intelectual dessa tecnologia; e pelo Instituto Nacional da Propriedade Industrial da República Federativa do Brasil (INPI), que expediu o registro do programa de computador por meio do processo de patente n˚ BR512024000239-1 (Albuquerque et al., 2024). A calculadora é fruto da pesquisa científica apresentada neste artigo e é disponibilizada gratuitamente conforme solicitação.
Em relação ao projeto de vigas de concreto armado em situação de incêndio, é importante inicialmente esclarecer que a primeira etapa do dimensionamento de uma estrutura para essa situação excepcional consiste na definição do tempo requerido de resistência ao fogo (TRRF). Esse parâmetro é determinado em função do tipo de ocupação ou uso e da altura da edificação, conforme NBR 14432 (ABNT, 2001) ou pelas ITs do Corpo de Bombeiros de cada Estado (precedem a ABNT).
Por conseguinte, a resistência ao fogo dos elementos estruturais presentes na edificação (vigas, lajes, pilares, etc.) deve ser verificada em função desse parâmetro, que compreende o tempo mínimo que esses elementos devem resistir quando submetidos ao incêndio-padrão ISO 834 (ISO, 1999).
A NBR 15200 (ABNT, 2012), norma brasileira para projeto de estruturas de concreto em incêndio, desenvolvida com base na norma europeia EN 1992-1-2 (ECS, 2004), permite que o dimensionamento das vigas seja realizado via métodos tabular, simplificado, avançado e experimental (esses métodos são detalhados em Albuquerque (2012)). Porém, o tabular é o único que pode ser aplicado diretamente, sem necessidade de programas de computador específicos ou ensaios em laboratório.
No método tabular, as vigas previamente dimensionadas à temperatura ambiente segundo a NBR 6118 (ABNT, 2023) devem atender, de modo geral, a valores mínimos de largura (bmín) e distância entre o eixo da armadura longitudinal inferior e a face do concreto exposta ao fogo (c1) para um determinado TRRF (Figura 1). Para dimensões intermediárias, permitem-se interpolações lineares. Esse método pode ser consultado na NBR 15200 (ABNT, 2012).
Figura 1
Dimensões mínimas de largura (bmín) e distância entre o eixo da armadura longitudinal inferior e a face do concreto exposta ao fogo (c1)
Fonte: Albuquerque (2012).
As tabelas foram elaboradas de forma empírica, com base em hipóteses conservadoras e aproximadas, que têm por referência limitar a 500 °C a temperatura no centro geométrico das barras da armadura tracionada, considerando essa a temperatura crítica do aço (ECS, 2004). A teoria representa uma simplificação da realidade, embora aceita pela comunidade científica.
Apesar de prático e usualmente adotado, esse método limita o dimensionamento a poucos valores tabelados, oferecendo apenas quatro alternativas de solução para cada TRRF. Isso impede, em diversas situações, que o profissional estude o problema de maneira mais efetiva e proponha outras soluções. Ademais, embora inspirado no EN 1992-1-2 (ECS, 2004), o método tabular para dimensionamento de vigas da NBR 15200 (ABNT, 2012) não segue estritamente a recomendação de que a temperatura máxima das armaduras longitudinais seja 500 °C.
Com base em revisão de literaturas, verificou-se que apesar de haver publicações sobre o comportamento de estruturas de concreto sob altas temperaturas que remontam ao final do século XIX e meados do século XX, como Freitag (1899) e Mörsch (1948), estudos específicos sobre vigas começaram a ser publicados apenas na década de 1980 e vem se desenvolvendo até os dias atuais. Pesquisadores adotaram diversos temas de estudo para analisar o comportamento ao fogo de vigas de concreto, e seus resultados foram extremamente relevantes para auxiliar na otimização do dimensionamento desses elementos estruturais para a situação de incêndio.
Zha (2003), Choi e Shin (2011), Reddy et al. (2015) e Shi et al. (2004), por exemplo, verificaram que adotar um cobrimento mais espesso para as armaduras ajuda a prolongar a resistência ao fogo de vigas simplesmente apoiadas produzidas com concreto de resistência convencional. Zha (2003) e Reddy et al. (2015) ainda concluíram que as dimensões das seções transversais de vigas simplesmente apoiadas exercem influência na resistência e que o aumento dessas dimensões também pode ser benéfico. Lin, Gustaferro e Abrams (1981) e Lin, Ellingwood e Piet (1988) apontaram que o esforço de cisalhamento não representa um problema significativo na resposta ao fogo de vigas contínuas, uma vez que a ruptura por flexão consiste no caso mais usual de colapso desses elementos. Lin, Ellingwood e Piet (1988) ainda destacaram que a resistência à flexão de vigas aquecidas é função, principalmente, do histórico de temperaturas na armadura. Lin, Gustaferro e Abrams (1981), Dwaikat (2009), Albuquerque et al. (2018), Bernhart (2004), Riva e Franssen (2008), Cvetkovska, Todorov e Lazarov (2013) e Wu e Lu (2009) mostraram os ganhos de resistência que podem ser obtidos quando os efeitos das restrições às deformações térmicas são considerados na análise do comportamento de vigas de concreto armado submetidas a temperaturas elevadas.
Contudo, ainda existe uma falta de pesquisadores que tenham se dedicado a aplicar os resultados de suas investigações na criação de ferramentas ou métodos práticos para efetivamente realizar o dimensionamento das vigas para a situação de incêndio. Como exceções, citam-se dois exemplos de trabalhos que seguiram a mesma linha deste artigo, ou seja, a apresentação de uma ferramenta/método que auxilie no cálculo da resistência ao fogo das vigas. Gao, Dai e Teng (2017) adotaram o modelo numérico de Gao et al. (2013) para a execução de análises paramétricas que serviram de base ao desenvolvimento de equações capazes de aferir o tempo de resistência ao fogo de vigas simplesmente apoiadas, considerando curvas de incêndio reais ou padronizadas. Kodur e Dwaikat (2011) propuseram uma equação simplificada para avaliar a resistência ao fogo das vigas, levando em conta vários parâmetros que influenciam no desempenho das mesmas, como cenário de incêndio, nível de carregamento, restrições axiais e rotacionais, dentre outros. Essa equação também foi desenvolvida com base nos resultados de um estudo paramétrico realizado mediante o modelo numérico que os autores construíram (Dwaikat, 2009; Kodur; Dwaikat, 2008a; Dwaikat; Kodur, 2008). Entretanto, para determinar a resistência ao fogo das vigas por meio das equações propostas por Gao, Dai e Teng (2017) e Kodur e Dwaikat (2011), uma série de equações intermediárias precisa ser solucionada.
Portanto, havia uma demanda para que se criasse uma ferramenta alternativa que fosse fácil de aplicar no dia a dia, assim como o método tabular, mas que envolvesse uma quantidade maior de soluções. A partir da verificação dessa necessidade, os autores deste artigo desenvolveram um método de dimensionamento que oferece resultados de resistência ao fogo para mais de 2300 modelos de seções transversais com diferentes dimensões e arranjos de armaduras, analisadas térmica e estruturalmente por meio de um programa de computador de elementos finitos. Para avaliar a resposta ao fogo das vigas, o método alternativo aplica o equilíbrio de forças na seção, admitindo as temperaturas reais atingidas nos materiais (concreto e aço).
Esses resultados contribuíram para expandir o espectro de soluções disponíveis para a comunidade técnica e científica, facilitando a viabilidade de projetos, e possibilitaram a criação da calculadora TRFVIG. Desenvolvida no formato de aplicativo, essa ferramenta computacional permite dimensionar vigas em situação de incêndio a partir da determinação do TRF, que deve ser igual ou superior ao TRRF.
Uma das vantagens da calculadora, que aplica o método de dimensionamento alternativo, é sua praticidade. O único dado de entrada que precisa ser realmente calculado para a sua aplicação consiste no parâmetro µ, facilmente definido pela relação entre o momento fletor solicitante de cálculo da seção em incêndio (MSd,fi) e o momento fletor resistente de cálculo da seção à temperatura ambiente (MRd). Os demais seis dados de entrada se referem apenas à definição de características da geometria/armadura da seção e do tipo de solicitação a que está submetida, identificando um caso de momento negativo (tração na fibra superior) ou positivo (tração na fibra inferior). Essas características da seção já são conhecidas do projeto à temperatura ambiente, etapa anterior obrigatória para a aplicação de qualquer método de dimensionamento ao fogo. Como será visto no Estado da arte, ainda não existem programas de computador semelhantes ao TRFVIG, que ofereçam uma abordagem simples e objetiva para o cálculo do TRF e para o dimensionamento de vigas de concreto armado em situação de incêndio.
Além disso, uma vez fundamentado em análises por elementos finitos e em hipóteses mais realísticas do que o método tabular (que impõe temperatura limite nas armaduras), o método alternativo de dimensionamento pode apresentar soluções mais econômicas. Elucida-se que o método alternativo segue as diretrizes da NBR 15200 (ABNT, 2012) para simulações termestruturais via método dos elementos finitos. Ademais, foi desenvolvido com a consideração dos fatores de redução das resistências dos materiais devido à exposição ao fogo (kc,𝜃, ks,𝜃) e dos coeficientes de ponderação adequados à situação excepcional (γc,fi, γs,fi, αfi) (vide Dimensionamento a temperaturas elevadas). Portanto, fornece resultados que, embora mais econômicos, garantem a segurança no projeto de vigas de concreto armado em situação de incêndio.
Estado da arte
Produção científica brasileira
Pesquisas científicas nacionais mais avançadas sobre vigas de concreto armado em situação de incêndio começaram a surgir a partir dos anos 2000. Castro (2005), Costa (2008), Kirchhof (2010), Silva (2011), Albuquerque (2012, 2018), Pereira et al. (2018) e Coelho (2018) adotaram programas de computador comerciais ou elaborados por outros autores para analisar tais elementos.
Maximiano (2018) criou novos módulos computacionais para a análise termestrutural de vigas de concreto armado aquecidas. Contudo, esses foram implementados em um programa de computador desenvolvido por terceiros (Silva, 2009). Pires (2023) também criou um programa no ambiente de uma ferramenta computacional não autoral, o MATLAB (MathWorks, 2009). Ao contrário do escopo deste artigo, Pires (2023) se concentrou na análise de confiabilidade de vigas de concreto armado submetidas a altas temperaturas.
Em contrapartida, determinados autores desenvolveram suas próprias ferramentas para avaliar numericamente os elementos estruturais em questão, representando as contribuições de origem acadêmica na produção científica brasileira voltada a ferramentas computacionais para a análise de vigas de concreto armado expostas ao fogo.
Nas ferramentas destinadas a esse fim, fundamentadas sobretudo no método dos elementos finitos (MEF), a resposta ao fogo do elemento estrutural é usualmente obtida com base em análises térmicas (definem a distribuição de temperaturas na viga) acopladas a análises estruturais (admitem os efeitos térmicos na degradação de propriedades mecânicas dos materiais, nas deformações do elemento e demais danos). Portanto, a priori, os campos térmicos são calculados em função do tempo. Em seguida, as temperaturas nodais são atribuídas como dados de entrada para as análises estruturais/mecânicas.
Dentre as soluções computacionais autorais, as de Figueiredo Júnior (2002), Ribeiro (2004), Miraval (2009) e Pierin, Silva e La Rovere (2015) definem exclusivamente o perfil de temperaturas nas seções das vigas, concentrando-se na resolução da primeira parte do problema.
Quanto às soluções autorais que se fundamentam na execução da análise completa (térmica mais estrutural), compartilhando função semelhante à calculadora TRFVIG, a de Caldas (2008) adota métodos de cálculo mais avançados, com análises ao nível do elemento. Por outro lado, Castro (2005), Klein Júnior (2011) e Padre et al. (2019) aplicam métodos com análises ao nível da seção1.
As ferramentas propostas por Caldas (2008) e Klein Júnior (2011) foram elaboradas puramente em linguagem computacional, com a descrição dos procedimentos e rotinas de cálculo. Em contraste, a de Padre et al. (2019) possui interface gráfica, enquanto Castro (2005) propôs planilhas de cálculo. Esses pesquisadores validaram suas ferramentas, demonstrando boas correlações ao comparar os resultados das análises termestruturais a dados experimentais, numéricos e/ou analíticos.
Entre as opções de mercado, que compreendem programas de computador disponíveis mediante licença para uso, verificou-se que o TQS (TQS Informática, 2023) e o AltoQi Eberick (Suporte AltoQi, 2023) são os mais relevantes para o escopo desta investigação. Eles representam ferramentas mais gerais, aplicáveis à elaboração de projetos estruturais completos de edifícios em concreto armado sob condições normais (sem fogo), abrangendo desde as fases de concepção até o detalhamento. No entanto, possuem módulos destinados à verificação de estruturas em situação de incêndio. Com base na pesquisa de referências realizada, não foram encontrados programas comerciais específicos para essa área de estudo. No TQS e no AltoQi Eberick, o comportamento ao fogo de vigas é analisado apenas via método tabular. Ambos vinculam seus procedimentos/rotinas de cálculo a interfaces gráficas.
Após comparar as soluções computacionais de origem acadêmica e as opções disponíveis no mercado com a solução proposta neste artigo, apresentam-se a seguir as principais conclusões obtidas.
Embora existam soluções computacionais para projetar vigas de concreto em incêndio sem necessidade de ferramentas auxiliares (Caldas, 2008; Padre et al., 2019; TQS Informática, 2023; Suporte AltoQi, 2023), ainda não foram desenvolvidos programas como o TRFVIG, cuja função principal é calcular o TRF e efetuar o dimensionamento de forma fácil, rápida e direta.
As soluções capazes de dimensionar as vigas por si sós e que aplicam métodos avançados ou simplificados (Caldas, 2008; Padre et al., 2019), necessitam que o usuário realize análises termestruturais via MEF. Em contrapartida, a ferramenta proposta fornece resultados finais de TRF oriundos dessas análises, efetuadas previamente pelos seus desenvolvedores.
Análises termestruturais exigem definição de vários parâmetros relacionados a propriedades térmicas e mecânicas dos materiais, modelagem do incêndio, condições de contorno e apoio, densidade de malha, etc. Portanto, não há programas nacionais que solicitem menos dados de entrada quando comparados ao TRFVIG, que requer apenas seis características da seção transversal da viga e um único dado que precisa ser calculado, o parâmetro µ.
As características da seção são conhecidas do projeto à temperatura ambiente, etapa anterior obrigatória para o dimensionamento ao fogo. Elas consistem (1) na largura e (2) altura da seção, (3) no sentido do momento fletor atuante (negativo ou positivo), (4) no número de camadas de armadura, (5) no cobrimento e (6) no arranjo das barras (quantidade e diâmetro). µ é uma relação entre MSd,fi e MRd (momentos fletores solicitante de cálculo em situação de incêndio e resistente de cálculo à temperatura ambiente, respectivamente), facilmente determinável por equações, sem necessidade de análises térmicas ou programas específicos da área de incêndio. Isso torna a calculadora uma opção viável para muitos profissionais. Além disso, funciona de forma independente, dispensando programas auxiliares gerais, como MATLAB (The MathWorks, 2009) ou Microsoft Office Excel (Microsoft® Office, 2006).
Não foram encontrados programas de computador que incluam um banco de dados composto por diversas soluções de dimensionamento para vigas de concreto armado em situação de incêndio, conforme proposta do TRFVIG. Embora tenha sido identificada uma ferramenta igualmente de origem acadêmica com interface gráfica para facilitar seu uso (Padre et al., 2019), essa ferramenta requer a execução de análise térmica.
A ferramenta baseada em planilhas (Castro, 2005), embora simplifique a utilização, é não-autônoma: não funciona sem dados da análise térmica, que precisa ser executada mediante outra ferramenta de cálculo, da mesma forma que a desenvolvida por Klein Júnior (2011). Ademais, as planilhas requerem Excel.
Os métodos de cálculo que respaldam os resultados do TRFVIG e dos demais programas de computador acadêmicos (Caldas, 2008; Castro, 2005; Klein Júnior, 2011; Padre et al., 2019) adotam hipóteses de cálculo mais refinadas que o método tabular, podendo conduzir a resultados menos conservadores em determinados casos. Na segunda etapa da solução do problema, que consiste na análise estrutural, os métodos aplicados nesses programas consideram as temperaturas reais alcançadas nos materiais da viga aquecida, conforme resultados da análise térmica. Em contrapartida, o método tabular adota uma temperatura limite para o aço, o que representa uma hipótese simplificada, de acordo com o EN 1992-1-2 (ECS, 2004). Para mais informações sobre as limitações do método tabular, pode-se consultar Gonçalves (2007) e Wit (2011).
Apesar dos programas comerciais possuírem interfaces gráficas, os mesmos não são específicos para análises de incêndio, exigindo o uso de sistemas multifuncionais. Na ferramenta sugerida, reúnem-se dados de entrada e resultados em uma única janela e a verificação da resistência ao fogo não está vinculada ao projeto estrutural completo.
Uma vez aplicada em computadores convencionais (mínimo esforço exigido), o grau de dificuldade não condiciona seu uso a especialistas da área de incêndio. O método de dimensionamento adotado na calculadora segue a NBR 15200 (ABNT, 2012) e o EN 1992-1-2 (ECS, 2004). Embora se assemelhe, de modo geral, ao método simplificado proposto nessa norma brasileira, o método alternativo adota hipóteses mais precisas, conforme esclarecido em Albuquerque, Silva e Rodrigues (2022). Resumidamente, o método simplificado da NBR 15200 (ABNT, 2012) adota procedimento de cálculo que considera as resistências médias dos materiais aquecidos, enquanto o método alternativo aplica valores de resistências reduzidas ponto a ponto. A partir dessas avaliações, foi possível destacar as vantagens da calculadora TRFVIG e confirmar a sua originalidade nos meios acadêmico e comercial brasileiros.
No campo dos trabalhos apresentados na Revista Ambiente Construído, verificou-se que ainda não foram publicados estudos sobre análises numéricas de vigas de concreto em situação de incêndio, assim como não foram identificadas pesquisas anteriores sobre a modelagem numérica desses elementos estruturais à temperatura ambiente, i.e., em condições normais (sem fogo). Até o momento, as publicações se concentraram em estudos experimentais sobre vigas de concreto à temperatura ambiente, fundamentadas exclusivamente em ensaios realizados em laboratório: Debella et al. (2024), Suk e Ferrari (2024), Vitor, Santos e Trautwein (2018) e Dalfré, Sarti Júnior e Araújo (2021). Portanto, não se identificou na literatura disponível deste periódico científico uma pesquisa numérica voltada à avaliação do comportamento ao fogo de vigas de concreto, tal como proposto neste estudo. Apesar disso, o tema relacionado a estruturas em situação de incêndio faz parte do escopo da revista. Como exemplo, citam-se trabalhos recentes sobre estruturas de concreto submetidas a temperaturas elevadas: Tutikian et al. (2021) e Pereira et al. (2024).
A análise do comportamento ao fogo de vigas de concreto armado é considerada de extrema importância, uma vez que o incêndio representa uma ação excepcional que deve ser considerada no projeto das estruturas (vide Considerações iniciais). O estudo da fase de projeto se insere na área do conhecimento “Tecnologia do Ambiente Construído”, escopo desta revista. Além disso, o concreto de resistência convencional, categoria de material aqui abordada, continua a ser tradicionalmente e amplamente utilizado na Construção Civil. Assim, ao apresentar o primeiro estudo sobre vigas de concreto em situação de incêndio nesta revista, este artigo de tema inédito na Ambiente Construído visa contribuir cientificamente, e de modo particular, ao avanço do seu estado da arte.
Ainda é válido mencionar que outros pesquisadores publicaram na Ambiente Construído estudos sobre programas de computador desenvolvidos tanto em ambientes comerciais quanto acadêmicos para a solução de problemas identificados nas áreas de Engenharia e Arquitetura: Freitas e Ruschel (2015) e Villa, Bruno e Santos (2020). Embora tenham sido voltados a temas de estudo diferentes daquele aqui abordado, esses programas foram igualmente criados no formato de aplicativos, assim como o proposto no presente artigo.
Cenário internacional
Na revisão de literaturas acadêmicas internacionais sobre estudos numérico-experimentais e numéricos, identificou-se um fator comum entre os trabalhos de Rigberth (2000), Zha (2003), Kang e Hong (2004), Bernhart (2004), Riva e Franssen (2008), Chythanya (2008), Gao et al. (2013), Cvetkovska, Todorov e Lazarov (2013), Reddy et al. (2015), Liao e Huang (2015), Albrifkani e Wang (2016), Kodur e Agrawal (2017), Gernay et al. (2023), Elshorbagi e Al Hamaydeh (2023), Liu et al. (2023), Boulvard, Pham e Bleyer (2024) e Szép, Rad e Habashneh (2024): para analisar a resposta ao fogo de vigas de concreto armado, os autores optaram por programas de computador comerciais ou pelo uso/modificação total ou parcial de soluções computacionais desenvolvidas por outros pesquisadores.
Contudo, houve exceções, uma vez que Dotreppe e Franssen (1985), Bratina et al. (2003), Biondini e Nero (2006), Gonçalves e Rodrigues (2007), Kodur e Dwaikat (2008b), Wu e Lu (2009), Štefan e Procházka (2009) e Guo e Shi (2011) criaram suas próprias ferramentas computacionais para a análise desses elementos. Alguns desses autores foram mais específicos ao explicar que as ferramentas propostas foram totalmente desenvolvidas no formato de programas de computador. Esses casos particulares são discutidos no parágrafo a seguir.
A principal diferença entre os programas de computador autorais, que aplicam sobretudo o MEF, é que Gonçalves e Rodrigues (2007) e Štefan e Procházka (2009) propuseram métodos simplificados de cálculo, enquanto Dotreppe e Franssen (1985), Kodur e Dwaikat (2008b), Wu e Lu (2009) e Guo e Shi (2011) propuseram métodos avançados. Somente Štefan e Procházka (2009) criaram uma interface gráfica para o programa de computador que desenvolveram, também com aspecto semelhante ao de um aplicativo. Em contraste, Dotreppe e Franssen (1985), Gonçalves e Rodrigues (2007), Kodur e Dwaikat (2008b), Wu e Lu (2009) e Guo e Shi (2011) criaram programas constituídos puramente por linguagens computacionais, apresentadas de modo que possam ser replicadas. Todos esses programas autorais foram submetidos a estudos de validação pelos seus desenvolvedores. Com base na pesquisa bibliográfica, não foram identificados trabalhos mais recentes sobre o desenvolvimento de programas de computador para dimensionamento de vigas de concreto armado expostas ao fogo.
Em relação ao âmbito comercial internacional, destacam-se como mais relevantes, seja pela popularidade ou por se relacionarem de forma mais direta ao escopo desta investigação, os seguintes programas de computador: DIANA (DIANA FEA, 2016), Abaqus (Abaqus, 2008) e Ansys (Ansys Inc., 2004), que são mais gerais e aplicáveis a diversas áreas das Engenharias e, além de várias potencialidades, calculam a capacidade resistente de vigas aquecidas; SAFIR (Franssen, 2005; Franssen; Kodur; Mason, 2002), VULCAN (Huang; Burgess; Plank, 2003), TCD (FSD, 2007), Beafire (INNOGET, 2023) e Concrete Fire - FIN EC (FCE, 2016), desenvolvidos exclusivamente para análise de estruturas em incêndio. Todos os programas comerciais se fundamentam no MEF. DIANA, Abaqus, Ansys, SAFIR e VULCAN adotam métodos avançados, enquanto o TCD, Beafire e Concrete Fire - FIN EC conduzem análises ao nível da seção via métodos simplificados, embasados principalmente nas equações de equilíbrio. Todos esses programas de computador comerciais possuem interfaces gráficas.
A partir de comparações entre as soluções disponíveis no âmbito internacional e a solução aqui proposta, verificou-se que apesar dos programas acadêmicos que aplicam métodos avançados e todos os comerciais possibilitarem a determinação da resistência ao fogo sem necessidade de ferramentas adicionais, ainda não existem recursos práticos para calcular esse parâmetro e que contemplem um banco de resultados abrangente. Essas soluções autônomas requerem análises termestruturais via MEF, sem opções que demandem menos dados de entrada. Gonçalves e Rodrigues (2007) não se enquadram nesse grupo porque o campo térmico não é calculado pelo próprio programa.
Embora Štefan e Procházka (2009) apresentem um programa acadêmico com interface gráfica, o mesmo depende do MATLAB, que requer licença para uso. O método da isoterma de 500 °C do EN 1992-1-2 (ECS, 2004), que respalda seus resultados, adota hipótese menos refinada que a calculadora, podendo conduzir a valores menos econômicos para o caso de vigas com armadura negativa. Isso ocorre devido à aproximação, a favor da segurança, da nova altura efetiva da seção transversal, dado que o método simula o decaimento da resistência do concreto aquecido a partir da redução de sua área resistente. Exemplos de aplicação do método da isoterma de 500 °C são demonstrados em Albuquerque (2012).
Os programas de computador comerciais, apesar das interfaces gráficas, não podem ser caracterizados como ferramentas práticas para fins de projeto. Alguns simulam de modo avançado o comportamento de estruturas, mas são usualmente utilizados apenas por pesquisadores da área. Assim, o TRFVIG se evidencia como contribuição inédita, inclusive internacionalmente.
Métodos
Dimensionamento a temperaturas elevadas
Os resultados da calculadora TRFVIG são provenientes de um método alternativo para dimensionamento de vigas aquecidas, denominado Método Gráfico. Esse método foi desenvolvido a partir de análises numéricas no TCD (Temperature Calculation and Design) v.5 (FSD, 2007), que realiza simulações termestruturais transientes bidimensionais considerando os efeitos deletérios do fogo em propriedades térmicas e mecânicas dos materiais.
O TCD é composto por um conjunto de programas. O módulo térmico, Super Tempcalc, realiza o cálculo das temperaturas em uma seção transversal aquecida, discretizada com elementos finitos. Essas temperaturas são então transferidas para o módulo estrutural Fire Design que, por meio da ferramenta CBeam, determina o momento fletor resistente da seção em situação de incêndio (MRd,fi), acoplando as análises térmicas às análises estruturais (Rigberth, 2000).
De acordo com Anderberg (2001) e FSD (2007), o Super Tempcalc adota uma abordagem que considera exclusivamente a transferência de calor, sem incluir a transferência de massa. Dessa forma, fenômenos como evaporação e migração de umidade no concreto não são admitidos. Contudo, segundo as diretrizes dos métodos avançados do EN 1992-1-2 (ECS, 2004), entende-se que a influência desses parâmetros pode ser conservadoramente desconsiderada. O Fire Design é integrado ao Super Tempcalc, uma vez que utiliza os resultados da análise térmica para incorporar os efeitos do fogo nas propriedades mecânicas a serem definidas no módulo estrutural. Por conseguinte, o programa é capaz de fornecer a capacidade resistente das vigas durante todo o processo de exposição ao fogo. O TCD permite gerar malhas com elementos finitos retangulares de 4 nós ou triangulares de 3 nós, em coordenadas cilíndricas ou retangulares. A discretização dos domínios do espaço e do tempo é realizada pelo método dos resíduos ponderados. Para a caracterização das seções, é possível utilizar modelos de materiais padronizados, disponíveis em seu banco de dados, ou definir novos materiais.
Para a concepção do método de dimensionamento e, consequentemente, da calculadora, adotaram-se seções retangulares com larguras de 14, 19, 25, 30 e 35 cm e alturas de 40, 50, 60 e 70 cm, superpostas por laje de 5 cm de espessura e 60 cm de largura. As dimensões das vigas foram adotadas com base em seções usualmente utilizadas em projetos realizados no Brasil. Em relação às lajes, adotou-se uma espessura relativamente pequena a favor da segurança, uma vez que 5 cm era o menor valor recomendado pela NBR 6118 (ABNT, 2007) para lajes maciças, nesse caso as de cobertura não em balanço. Posteriormente ao estudo realizado, a norma vigente NBR 6118 (ABNT, 2023) passou a indicar 7 cm de espessura mínima. Porém, considerando que as vigas que serão dimensionadas a partir desse método terão lajes com espessuras de 7 cm no mínimo e que o aumento da espessura é diretamente proporcional à massa de concreto que absorve calor, as vigas com lajes mais espessas estarão em condição menos crítica em comparação àquelas utilizadas na construção do método alternativo. Portanto, o método é válido e pode ser aplicado para esses casos.
Nas análises térmicas das seções, admitiu-se exposição ao incêndio-padrão ISO 834 (ISO, 1999) nas três faces da viga (laterais e inferior) e sob a laje (Figura 2). As faces não expostas ao fogo (laterais e superior da laje) foram consideradas como adiabáticas, a favor da segurança. Adotaram-se parâmetros físicos e térmicos do concreto variáveis com a temperatura, tais como condutividade térmica (λc,𝜃c), calor específico (cp,𝜃c) e massa específica (ρc,𝜃c), de acordo com a NBR 15200 (ABNT, 2012), conforme indicado na Tabela 1. No cálculo do calor específico, considerou-se umidade relativa de 1,5% em peso do concreto e, quanto à determinação da massa específica, admitiu-se o valor de 2400 kg/m3 para essa grandeza à temperatura ambiente (ρ), como proposto pela NBR 6118 (ABNT, 2023). O coeficiente de transferência de calor por convecção (αc) igual a 25 W/(m2 oC) e a emissividade resultante (εres) nas faces expostas ao fogo igual a 0,7 também foram definidos segundo a NBR 15200 (ABNT, 2012). Assumiu-se o incremento de tempo igual a 0,002 h.
Figura 2
Exemplo de viga adotada para análises térmicas
Fonte: adaptado de Albuquerque, Silva e Rodrigues (2022).
Tabela 1
Propriedades do concreto em função das temperaturas adotadas nas análises térmicas, definidas conforme as equações propostas pela NBR 15200 (ABNT, 2012)
Temperaturado concreto(θc) [°C]
Condutividadetérmica (λc,𝜃c)[W/(m °C)]
Temperaturado concreto(θc) [°C]
Calorespecífico(cp,𝜃c) [J/(kg °C)]
Temperaturado concreto(θc) [°C]
Massaespecífica(ρc,𝜃c) [kg/m3]
20
1,3330
20
900
20
2400,000
200
1,1108
100
900
100
2400,000
300
1,0033
100
1470
115
2400,000
400
0,9072
115
1470
116
2399,435
500
0,8225
200
1000
200
2352,000
600
0,7492
300
1050
300
2316,000
700
0,6873
400
1100
400
2280,000
800
0,6368
500
1100
500
2259,000
900
0,5977
1200
1100
1200
2112,000
1000
0,5700
-
-
-
-
1100
0,5537
-
-
-
-
1200
0,5488
-
-
-
-
Elucida-se que na determinação do campo de temperaturas em uma seção de concreto armado, desconsiderando-se o spalling2, modela-se apenas a massa de concreto, sem a armadura. A explicação para essa hipótese é que devido à massa desse material ser muito superior à pequena massa das barras, assume-se que o aço irá absorver instantaneamente a temperatura do concreto. Por isso, consideram-se apenas as propriedades térmicas desse material. Porém, para o cálculo da capacidade resistente das seções aquecidas, modela-se a armadura e, por conseguinte, aplica-se a resistência à tração do aço, variável ao longo do tempo de exposição ao fogo, assim como a resistência à compressão do concreto. A consistência dessa hipótese foi inicialmente revelada por Ehm (1967), que a partir de resultados de análises térmicas computacionais verificou que as temperaturas dos centros geométricos das barras da armadura correspondiam às mesmas temperaturas obtidas nessas posições ao se assumir uma seção transversal composta de forma homogênea por concreto simples.
O domínio foi discretizado por meio de uma malha de elementos finitos retangulares de quatro nós com lados de 0,005 m. Adotou-se esse valor em virtude de análises prévias apresentadas em Silva (2011) nas quais se verificou, a partir de estudo de sensibilidade, que malhas com elementos de 0,01 m conduziam a momentos relativos (µ), parâmetro que será detalhado mais adiante, bastante próximos daqueles obtidos mediante malha com elementos de 0,005 m, demostrando uma variação inferior a 0,5%. Além disso, essa dimensão foi adotada por representar o máximo esforço computacional permitido pelo equipamento disponível.
Após a inclusão desses dados de entrada, o TCD soluciona a equação diferencial para fluxos bidimensionais de calor, indicada pela Equação 1, que é derivada do princípio da conservação de energia e cuja relação constitutiva adotada consiste na Lei de Fourier, lei fundamental que rege a propagação de calor por condução (FSD, 2007).
Q
=
−
ρ
c
,
θ
c
c
p
,
θ
c
∂
θ
∂
t
+
∂
∂
x
λ
c
,
θ
c
∂
θ
∂
x
+
∂
∂
y
λ
c
,
θ
c
∂
θ
∂
y
Eq. 1
Onde:
Q é a quantidade de calor gerada no interior do concreto por unidade de volume e tempo [J/(m3 s)];
t é o tempo [s];
x e y são as coordenadas cartesianas [adimensional];
θc é a temperatura do concreto [°C];
ρc,𝜃c é a massa específica do concreto à temperatura θc [kg/m3];
cp,θc é o calor específico do concreto à temperatura θc [J/(kg °C)]; e
λc,θc é a condutividade térmica do concreto à temperatura θc [W/(m °C)].
Figura 3
Armaduras inseridas em modelo de viga para análises estruturais: uma camada positiva (a), duas camadas positivas (b), uma camada negativa (c) e duas camadas negativas (d)
Fonte: Albuquerque (2012).
As condições de contorno aplicadas consideram a transferência de calor por meio dos processos de convecção e radiação, conforme apontado na Equação 2.
φ
=
α
c
θ
g
−
θ
c
+
ε
res
σ
θ
g
+
273
4
−
θ
c
−
273
4
Eq. 2
Onde:
φ é o fluxo de calor convectivo e radioativo, por unidade de área da superfície de concreto [W/m2];
θg é a temperatura dos gases [°C];
θc é a temperatura na superfície de concreto [°C];
αc é o coeficiente de transferência de calor por convecção [W/(m2 °C)];
εres é a emissividade resultante nas faces expostas ao fogo [adimensional]; e
σ é a constante de Stephan-Boltzmann (adotada igual a 5,67 x 10-8) [W/(m2 °C4)].
Nas análises estruturais, consideraram-se armaduras com barras de diâmetros (ϕ) de 10, 12,5, 16, 20 e 25 mm, dispostas em uma (Figuras 3a e 3c) e duas camadas (Figuras 3b e 3d), positivas (Figuras 3a e 3b) e negativas (Figuras 3c e 3d). Adotaram-se cobrimentos de 25, 30 e 40 mm e estribos com diâmetro (ϕt) de 5 mm. A quantidade máxima de aço foi inserida em cada largura, respeitando os valores de espaçamento mínimo livre entre faces das barras longitudinais, indicados pela NBR 6118 (ABNT, 2023).
A resistência característica do concreto à compressão (fck) foi estipulada igual a 25 MPa e a resistência do aço à tração (fyk) igual a 500 MPa. Os coeficientes de ponderação das resistências (γc,fi, γs,fi) foram admitidos iguais a 1,0 para os materiais expostos ao fogo e o redutor do valor de cálculo da resistência à compressão do concreto em incêndio (αfi) igual a 1,0, conforme NBR 15200 (ABNT, 2012). Os fatores de redução das resistências dos materiais devido às temperaturas elevadas (kc,𝜃, ks,𝜃) também foram definidos de acordo com a NBR 15200 (ABNT, 2012).
Mediante esses dados de entrada admitidos no módulo estrutural e já de posse dos resultados das temperaturas atingidas na seção, definidas no módulo térmico, o TCD calcula o momento fletor resistente da viga em situação de incêndio (MRd,fi) com base unicamente no equilíbrio de forças, sem limitar a temperatura no aço. O programa utiliza discretização com malha de elementos finitos para aplicar a somatória das forças representativas das barras da armadura e dos elementos de concreto comprimido (Figura 4a), para então determinar as forças resultantes da seção (Fsd,fi e Fcd,fi), Figura 4b. Considera plastificação total tanto do concreto quanto do aço e deformações específicas limites não são impostas. Em Albuquerque (2012), apresentam-se exemplos nos quais valores de MRd,fi são definidos manualmente, considerando cada uma das etapas que compõem os procedimentos de cálculo do TCD.
Figura 4
Seção de concreto armado discretizada com malha de elementos finitos (a) e equilíbrio de forças resultantes (b)
Fonte: Albuquerque (2012).
Portanto, os principais resultados definidos nas análises térmicas e estruturais são os campos de temperaturas (Figura 5) e os valores de MRd,fi (Figura 6), respectivamente. O TCD ainda fornece gráficos que apresentam o parâmetro μ da Equação 3, em função do tempo de aquecimento. As curvas com essa relação foram adotadas para elaborar este método de dimensionamento. Note-se que a segurança é atendida quando MSd,fi ≤ MRd,fi. Logo, ao se admitir MSd,fi = MRd,fi, é possível encontrar o tempo máximo de resistência ao fogo (TRF) da viga. Assim, a Equação 3 se transforma na Equação 4. A Figura 7 apresenta um gráfico com exemplos dessas curvas.
Figura 5
Campo térmico em determinada viga após 180 min de exposição ao fogo
Fonte: Albuquerque (2012).
Figura 6
Curva do momento fletor resistente em incêndio vs tempo de aquecimento
Fonte: adaptado de Albuquerque (2012).
μ
=
M
R
d
,
f
i
M
R
d
Eq. 3
μ
=
M
S
d
,
f
i
M
R
d
Eq. 4
Figura 7
Gráfico para dimensionamento de vigas de concreto armado com momentos positivos, concreto de resistência característica à compressão (fck) entre 25 e 50 MPa (classes C25 a C50), e aço de resistência à tração (fyk) igual a 500 MPa (classe CA-50)
Fonte: adaptado de Albuquerque (2012).
Onde:
MRd é o momento fletor resistente de cálculo à temperatura ambiente [kN cm];
MRd,fi é o momento fletor resistente de cálculo em situação de incêndio [kN cm];
MSd,fi é o momento fletor solicitante de cálculo em situação de incêndio [kN cm]; e
µ é o momento relativo [adimensional].
Uma vez que a ação térmica tem duração extremamente curta e baixa probabilidade de ocorrer durante a vida útil da edificação, os esforços atuantes em incêndio (Sd,fi) podem ser definidos pela combinação excepcional de ações, sendo reduzidos em relação aos valores utilizados à temperatura ambiente. A NBR 8681 (ABNT, 2004) recomenda a Equação 5. Entretanto, de acordo com a NBR 15200 (ABNT, 2012), na ausência de qualquer solicitação gerada pelas deformações impostas em situação de incêndio, pode-se admitir, alternativamente, que as solicitações de cálculo em incêndio sejam calculadas admitindo-as iguais a 70% das solicitações de cálculo em situação normal, tomando-se apenas as combinações de ações que não incluem o vento. Permite-se, portanto, a seguinte simplificação: Sd,fi = 0,7 Sd, (sendo Sd o valor de cálculo da ação à temperatura ambiente).
S
d
,
f
i
=
1
,
2
Σ
i
=
1
m
S
G
i
,
k
+
0
,
7
Σ
j
=
1
n
ψ
2
S
Q
j
,
k
Eq. 5
Onde:
Sd,fi é o valor de cálculo da ação na combinação excepcional [kN];
SGi,k é o valor característico da ação permanente i [kN];
SQj,k é o valor característico da ação variável j [kN]; e
ψ2 é o fator de combinação para valores reduzidos das ações variáveis [adimensional].
A favor da segurança, recomenda-se que o MRd a ser admitido como dado de entrada para uso do método seja calculado conforme a NBR 6118 (ABNT, 2023) ou versão mais recente, aplicando-se as deformações específicas limites. MRd é determinado pelo programa de computador TCD com base na mesma hipótese indicada para a definição de MRd,fi, ou seja, por equilíbrio de forças, sem a imposição de deformações específicas limites para ambos os materiais, mas considerando os coeficientes adequados à situação normal. No entanto, o TCD realiza uma simplificação ao admitir que a linha neutra da seção à temperatura ambiente é igual à obtida para a situação de incêndio. Devido a esse artifício, os gráficos µ vs TRF se tornam a favor da segurança para valores distintos de fck, apesar de terem sido construídos com a consideração da classe C25, amplamente utilizada em projetos de estruturas de concreto armado. Contudo, sugere-se apenas que o valor de fck para uso do método seja menor ou igual a 50 MPa (classe C50) para evitar concretos de alta resistência, fora do escopo desta pesquisa.
É importante destacar que foi realizado um estudo de validação do método de dimensionamento alternativo, que fornece os resultados da calculadora TRFVIG. O momento fletor resistente da seção de uma viga de concreto armado aquecida (MRd,fi) obtido por meio do TCD representa a principal variável utilizada para a concepção desse método e, por conseguinte, da calculadora. Logo, adotaram-se algumas seções de vigas adequadamente escolhidas para serem representativas e seus respectivos valores de MRd,fi foram determinados a partir de diferentes métodos:
método direto do TCD (apresentado nesta Seção Dimensionamento a temperaturas elevadas);
método simplificado da NBR 15200 (ABNT, 2012);
método proposto pelos autores deste artigo, que sugeriram uma simplificação do método (b);
método da isoterma de 500 °C, recomendado pelo EN 1992-1-2 (ECS, 2004); e
método adotado na ferramenta computacional FNC-FOGO (Klein Júnior, 2011).
Ao comparar os resultados provenientes tanto de métodos simplificados ((a) a (d)) quanto de um método mais avançado (e), verificou-se que, para efeito de projeto, todos conduziram a valores muito próximos, demonstrando que os resultados do método aplicado na calculadora (a) são suficientemente precisos. Dessa forma, a determinação de MRd,fi com o auxílio do programa de computador TCD foi validada e justificada para esta pesquisa, uma vez que seria inviável realizar esses cálculos manualmente para os diversos modelos de vigas considerados na elaboração do método aqui discutido. O estudo de validação e cada um dos procedimentos definidos para cálculo de MRd,fi são discutidos detalhadamente em Albuquerque, Silva e Rodrigues (2022), referência que também apresenta mais informações sobre as análises numéricas conduzidas para o desenvolvimento do método alternativo para dimensionamento.
Extraindo do TCD os valores de µ para cada viga, construíram-se 204 planilhas no Excel v.2007 (Microsoft® Office, 2006), semelhantes à Tabela 2. Com base em todos os dados dessas planilhas, desenvolveu-se a calculadora do TRF de vigas de concreto armado. Os autores também utilizaram esses dados para criar uma ferramenta analítica com abordagem não-computacional (apresentada em Albuquerque, Silva e Rodrigues (2022)), que envolveu a seleção apenas dos resultados mais representativos para compor gráficos, ilustrados integralmente em Albuquerque (2012, 2014) e Silva (2012). Dentre curvas próximas, escolhia-se aquela que conduzia a menores TRFs, a favor da segurança. As curvas desconsideradas estavam pouco afastadas, com distâncias de 10 a 15 min, aproximadamente.
Tabela 2
µ em função das características da seção da viga e TRF
1 camada positiva
Viga 14x40 (cobrimento = 2,5 cm / ϕt = 5 mm)
μ
ϕ [mm]
t [min]/ϕ
0
15
30
45
60
75
90
105
120
135
150
165
180
10
2ϕ10
1,0000
1,0000
1,0000
1,0000
0,7228
0,4479
0,2605
0,1804
0,1203
0,0955
0,0738
0,0634
0,0566
3ϕ10
1,0000
1,0000
1,0000
1,0000
0,8188
0,5458
0,3370
0,2236
0,1505
0,1114
0,0857
0,0714
0,0607
12,5
2ϕ12,5
1,0000
1,0000
1,0000
1,0000
0,7714
0,4857
0,2907
0,1966
0,1314
0,1014
0,0793
0,0656
0,0585
3ϕ12,5
1,0000
1,0000
1,0000
1,0000
0,8580
0,5804
0,3642
0,2418
0,1617
0,1187
0,0908
0,0741
0,0627
16
2ϕ16
1,0000
1,0000
1,0000
1,0000
0,8343
0,5449
0,3398
0,2199
0,1491
0,1100
0,0872
0,0690
0,0614
20
2ϕ20
1,0000
1,0000
1,0000
1,0000
0,9062
0,6168
0,3985
0,2509
0,1727
0,1201
0,0965
0,0758
0,0647
Na Figura 7, um desses gráficos mostra que uma curva pode representar mais de uma configuração de armadura. Em contrapartida, utilizaram-se todos os resultados para compor o banco de dados da calculadora. Tratando-se de uma ferramenta computacional, não havia necessidade de selecionar curvas para torná-la mais prática. Por isso, seus resultados de TRF podem eventualmente ser maiores do que aqueles encontrados pelo uso dos gráficos.
Desenvolvimento da calculadora TRFVIG
Detalhamento da estrutura
A Figura 8 apresenta um fluxograma que elucida as etapas do processo de criação da estrutura do TRFVIG, possibilitando obter uma visão geral do programa de computador, compreender seu desenvolvimento e de que forma está organizado. Itens que compõem a estrutura são discutidos em detalhes a seguir.
Figura 8
Fluxograma do desenvolvimento da estrutura da calculadora TRFVIG
Banco de dados com soluções do método de dimensionamento
Empregaram-se os resultados do método apresentado em Dimensionamento a temperaturas elevadas na elaboração do banco de dados, cuja inserção/alimentação foi realizada pela reorganização e transferência desses resultados para arquivos de texto, onde foram inseridos no formato de tabelas. Para que os dados pudessem ser lidos pelo programa, cada tabela foi assim reconfigurada (Figura 9):
Figura 9
Exemplo de configuração de uma das tabelas inseridas no arquivo texto com o banco de dados da calculadora
primeira linha: representa as características dos dados da tabela, indicando largura (bw) e altura (h) da seção, cobrimento (c), número de camadas em que armaduras estão distribuídas (uma ou duas) e sentido do momento fletor atuante (M, positivo ou negativo) – as dimensões estão indicadas em cm;
segunda linha: indica os valores de TRF estabelecidos como base para a obtenção dos resultados das análises numéricas termestruturais – tempos em min; e
linhas em diante: apresentam os valores de µ para cada um dos TRFs preestabelecidos, sendo que a primeira coluna indica a armadura correspondente. 2f10, por exemplo, refere-se à armadura 2ϕ10 – µ é adimensional, pois representa momentos relativos.
Estabeleceu-se uma ordem para alimentar essas tabelas, que foram inseridas gradualmente para a realização de testes de funcionamento em vários estágios da inserção dos dados. Em cada conjunto de 9 ou 12 tabelas salvo no arquivo com extensão .txt, confirmava-se o número de novas tabelas e as características dos dados inseridos, além de múltiplas verificações dos resultados. Inseriram-se as tabelas na seguinte ordem: vigas com armaduras (1) positivas em uma camada; (2) positivas em duas camadas; (3) negativas em uma camada e (4) negativas em duas camadas. Na Figura 10, há um esquema com a relação das tabelas existentes para esses casos, indicando as características dos seus dados, além do número total de tabelas e soluções disponíveis na calculadora.
Figura 10
Características das vigas que compõem o banco de dados da calculadora
Implementação
Toda a implementação do programa foi realizada em linguagem C# sob a plataforma Microsoft .NET® Framework (v. 4.5.1). Lançada no início dos anos 2000, essa linguagem de programação é conhecida pela facilidade de uso, segurança e recursos abrangentes. Assim, torna-se adequada para criar uma variedade de aplicativos, incluindo desktops, como o TRFVIG.
O principal desafio na implementação consistiu em definir como o volumoso conjunto de resultados iria ser carregado no banco de dados. Após algumas análises iniciais, optou-se pela conversão em tabelas, que posteriormente foram transformadas num arquivo binário, no qual os dados são codificados em formato composto por sequência de zeros (0) e uns (1). Portanto, o banco de dados dispõe de leve camada de proteção, para assegurar em certa medida sua confidencialidade e integridade.
Interface gráfica
Construiu-se a interface em Windows Presentation Foundation® (WPF). Logo, a calculadora é compatível com as recentes versões do sistema operacional Windows (7 ou posterior), desde que o Framework esteja devidamente instalado no computador. O instalador foi criado no Inno Setup®. Priorizou-se a criação de uma interface-usuário simples, lógica e intuitiva, agrupando todos os dados de entrada e resultados em apenas uma janela. A Figura 11 mostra a tela inicial.
Figura 11
Tela inicial da calculadora TRFVIG: dados de entrada (painel esquerdo) e considerações gerais (painel direito)
Assim que a calculadora é carregada, o painel direito exibe informações gerais e avisos. O painel esquerdo é sempre dedicado aos dados de entrada correspondentes às variáveis das tabelas do banco de dados. Cada tabela está organizada com resultados µ vs TRF que dependem das dimensões da seção, sentido do momento e arranjo da armadura. Por isso, organizaram-se os dados na ordem em que devem ser obrigatoriamente preenchidos, para identificar corretamente a tabela associada à viga analisada. Os dados de entrada que precisam ser fornecidos são:
dimensões da seção: largura (bw) e altura (h);
sentido do momento fletor atuante: definir se há tração na fibra superior (momento negativo) ou inferior (momento positivo);
características da armadura: número de camadas em que está distribuída (1 ou 2); cobrimento (c); quantidade e diâmetro (f) das barras de cada camada; e
parâmetro µ: relação entre MSd,fi e MRd (Equação 4).
Para definir bw, h, número de camadas, c e armaduras, clica-se na seta apontando para baixo do campo correspondente à cada um desses itens para abrir listas com opções. Para o sentido do momento, seleciona-se “tração na fibra superior (-)” ou “tração na fibra inferior (+)”. Para a definição de µ, há duas opções: inserir diretamente o seu valor na caixa de texto da tela inicial ou determiná-lo pela entrada dos valores de MSd,fi e MRd. Na segunda opção, a calculadora determina a relação entre esses momentos, conforme ilustra a janela auxiliar “Cálculo do coeficiente µ”, apresentada na Figura 11.
O processamento é realizado por um único botão “Calcular TRF” e, em seguida, uma visão consolidada dos resultados é apresentada instantaneamente no painel direito (tela final ilustrada na Figura 12). Os principais dados de saída fornecidos são:
Figura 12
Tela de resultados da calculadora TRFVIG: dados de entrada (painel esquerdo) e memorial de cálculo, com TRF da viga e gráfico µ vs TRF (painel direito)
TRF da viga; e
gráfico µ vs TRF.
Filtros de busca e relatório de resultados
Implementaram-se filtros que buscam no banco de dados os resultados de TRF correspondentes aos dados de entrada. Quando o µ definido pelo usuário difere dos valores originalmente disponíveis, o programa realiza uma interpolação linear. Nenhum tipo de extrapolação foi incluído nos cálculos. Também foi estabelecido um método de consulta ao banco de dados, para otimizar o tempo de cálculo.
Junto aos principais resultados, o programa gera um relatório em formato de memorial de cálculo, ressaltando o aviso sobre seu campo de aplicação (destacado em amarelo), além de um resumo dos dados de entrada (Figura 12). Apesar dos inúmeros testes de funcionamento, os desenvolvedores não assumem responsabilidade pelos resultados, que devem ser avaliados e validados pelo usuário (Figura 11).
Módulos e funções
O ambiente do programa TRFVIG foi organizado em módulos, dividindo-o em partes interconectadas e facilmente gerenciáveis para simplificar o código-fonte. Cada módulo contém funções que desempenham papéis específicos para seu funcionamento.
Módulo de leitura e proteção do banco de dados
Esse módulo possui funções para:
leitura e coleta de informações das tabelas do banco de dados, desempenhando papel relevante no acesso aos resultados, pois o programa se baseia principalmente na interpretação de valores armazenados;
proteção do banco de dados, convertendo-o em arquivo binário; e
definição de filtros de busca e tratamento dos dados, que efetuam procura minuciosa, seguida de seleção de dados específicos dentre os inúmeros dados das tabelas.
Esse processo envolve várias etapas: uma função identifica as tabelas com dados correspondentes à largura especificada, outra identifica as tabelas com a altura escolhida, seguidas por funções que localizam as tabelas correspondentes ao cobrimento da armadura, número de camadas, posição do momento e assim por diante. Executam-se essas etapas sucessivas até que apenas uma tabela seja selecionada para a viga analisada.
Módulo de criação da interface gráfica
Em um programa escrito em C#, uma linguagem interpretada, a interface gráfica é essencial para interação com o usuário, tornando a experiência mais eficaz e amigável. Para projetar um leiaute intuitivo, adotaram-se funções para criar os seguintes elementos (Figuras 11 e 12):
janelas e painéis: as janelas compreendem o quadro principal da interface, com os botões, barras de rolagem, caixas de texto, entre outros; há uma janela auxiliar para calcular µ, além dos painéis implementados para organizar elementos relacionados;
botões: projetados para executar ações específicas ao serem clicados; “Sobre” disponibiliza informações gerais sobre o TRFVIG, “...” permite definir manualmente MSd,fi e MRd, “Reiniciar” apaga os dados inseridos, possibilitando uma nova análise;
caixas de texto: permitem ao usuário identificar µ inserindo diretamente o seu valor ou fornecendo os valores de MSd,fi e MRd, para então o próprio programa efetuar o cálculo;
barras de rolagem: as barras de rolagem verticais facilitam a seleção de dados de entrada, ao permitir a navegação em informações que não cabem integralmente na janela visível do programa; para definir bw, por exemplo, há uma barra com opções de larguras;
rótulos: elementos que melhoram a compreensão dos dados de entrada, tornando-se visíveis ao posicionar o cursor sobre esses dados; há um rótulo para h, informando “Altura da viga considerando a espessura da laje/mesa colaborante”, um para µ, explicando como esse parâmetro deve ser calculado, etc.;
pop-ups: exibem mensagens de erro e alertas; por exemplo, se o usuário inserir µ ˃ 1, uma janela avisará que o valor fornecido está fora do intervalo disponível; as janelas pop-up também orientam que todos os dados de entrada devem ser preenchidos e na ordem solicitada; e
gráficos e imagens: a curva µ vs TRF fornece uma representação gráfica dos resultados, facilitando a análise dos dados gerados.
Módulo de determinação dos resultados
Identificada a tabela que contém os dados especificados pelo usuário, acionam-se as funções para cálculo do TRF. Conforme fluxograma da Figura 13, o resultado pode ser obtido de duas maneiras:
Figura 13
Fluxograma com procedimento de cálculo do programa de computador TRFVIG
se µ definido pelo usuário coincidir com um dos valores de µ da tabela selecionada para o caso em análise, o programa calcula o TRF da viga exclusivamente com base na seleção do resultado previamente armazenado e, portanto, já disponível no banco de dados; e
se µ diferir dos valores originalmente contidos no banco de dados, o programa efetua uma interpolação linear dos valores de µ e TRF disponíveis, para então definir o TRF.
As funções pós-cálculo apresentam o resultado no relatório, integrando-se àquelas responsáveis por compilar e exibir informações gerais sobre a análise executada. Especificamente, essas funções:
definem os requisitos do relatório, identificando quais informações e resultados devem ser incluídos;
determinam o formato do relatório, que inclui texto e gráficos;
consideram os requisitos de formatação, como fontes, paleta de cores e estilos de apresentação; e
coletam e compilam dados e resultados para composição do documento.
Resultados e discussões
Para apresentar resultados da calculadora TRFVIG, adotaram-se vigas simplesmente apoiadas e contínuas, descritas na Figura 14 e nos Quadros 1–3, em que pk representa o valor característico do carregamento uniformemente distribuído, L o comprimento do vão, pd,fi o valor de cálculo do carregamento uniformemente distribuído em incêndio, ϕt o diâmetro dos estribos, c o cobrimento e As a área de aço da armadura, distribuída em uma ou duas camadas. Visto a simetria dos dois vãos dos modelos de vigas contínuas adotados, os cálculos foram realizados somente para um trecho do elemento estrutural, conforme esquema da Figura 14b. Adotaram-se os modelos apresentados em Albuquerque (2012), dimensionados à temperatura ambiente conforme NBR 6118 (ABNT, 2023). 60% de ações permanentes e 40% de variáveis foram os valores adotados para definição do carregamento em incêndio, via Equação 5. Estipulou-se o uso de concreto com fck igual a 25 MPa e aço com fyk de 500 MPa. Todas as vigas foram consideradas superpostas por lajes com largura bf de 60 cm e espessura hf de 5 cm.
Figura 14
Características das vigas adotadas nos exemplos de aplicação: modelo de viga simplesmente apoiada (a), esquema estático representativo de trecho de viga contínua com dois vãos simétricos (b), e seção transversal das vigas simplesmente apoiadas e contínuas (c)
Fonte: adaptado de Albuquerque (2012).
Quadro 1
Exemplos de vigas simplesmente apoiadas
Viga
pk [kN/m]
L [m]
bw [cm]
h [cm]
Dimensionamento àtemperatura ambiente
Carregamentoem incêndio
a
55
4
35
40
ϕt = 5 mm; c = 25 mm;As+ = 6ϕ16 mm(1 camada)
Bibliotecaψ2 = 0,6pd,fi = 49 kN/m
b
20
4,5
25
45
ϕt = 5 mm; c = 40 mm;As+ = 6ϕ10 mm(1 camada)
Edifício residencialψ2 = 0,3pd,fi = 16 kN/m
c
30
5
14
50
ϕt = 5 mm; c = 30 mm;As+ = 4ϕ16 mm(2 camadas)
Escritórioψ2 = 0,4pd,fi = 25 kN/m
d
20
6
19
60
ϕt = 5 mm; c = 25 mm;As+ = 3ϕ16 mm(1 camada)
Edifício residencialψ2 = 0,3pd,fi = 16 kN/m
Fonte: adaptado de Albuquerque (2012).
Quadro 2
Exemplos de vigas contínuas
Viga
pk [kN/m]
L [m]
bw [cm]
h [cm]
Dimensionamento à temperatura ambiente
Carregamento em incêndio
Sem redistribuição
Com redistribuição
a
55
5,5
35
55
As+ = 4ϕ16 mm(1 camada)As- = 8ϕ16 mm(1 camada)
As+ = 8ϕ12,5 mm(1 camada)As- = 4ϕ20 mm(1 camada)
Bibliotecaψ2 = 0,6pd,fi = 49 kN/m
ϕt = 6,3 mm; c = 30 mm
b
20
6
19
60
As+ = 4ϕ10 mm(1 camada)As- = 3ϕ16 mm(1 camada)
As+ = 3ϕ12,5 mm(1 camada)As- = 4ϕ12,5 mm(1 camada)
Edifício residencialψ2 = 0,3pd,fi = 16 kN/m
ϕt = 5 mm; c = 25 mm
c
40
7
30
70
As+ = 6ϕ12,5 mm(1 camada)As- = 12ϕ12,5 mm(2 camadas)
As+ = 12ϕ10 mm(2 camadas)As- = 8ϕ12,5 mm(2 camadas)
Arquibancada ψ2 = 0,4pd,fi = 33 kN/m
ϕt = 5 mm; c = 40 mm
Fonte: adaptado de Albuquerque (2012).
Quadro 3
Combinações de redistribuição de momentos em vigas contínuas
Casos de estudo
Redistribuição de momentos
Temperaturaambiente
Situação de incêndio
1
2
3
4
Fonte: adaptado de Albuquerque (2012).
Ao contrário do projeto em condições normais, momentos podem ser redistribuídos do positivo para o negativo em situação de incêndio, pois a armadura negativa possui resistência menos prejudicada que a positiva, diretamente exposta ao fogo na parte inferior da viga. A calculadora permite essa redistribuição, uma vez que contempla armaduras tanto positivas quanto negativas. O coeficiente de redistribuição em incêndio (δfi) pode ser maior que o adotado à temperatura ambiente (δ), devido à maior capacidade de rotação dos apoios nessa condição de aquecimento. Contudo, por segurança, adotou-se nesses exemplos δfi = δ, conforme limites da NBR 6118 (ABNT, 2023) para estruturas de nós fixos (δ = 0,75). Estipularam-se diversas combinações de redistribuição de momentos fletores solicitantes, indicadas no Quadro 3.
Nas Figuras 15 e 16, apresentam-se os TRFs das vigas estudadas, comparando-os aos métodos gráfico e tabular, respectivamente. Para esclarecer os procedimentos para uso da calculadora TRFVIG e seus resultados, discutem-se inicialmente alguns casos específicos dos exemplos.
No modelo b de viga simplesmente apoiada (Figuras 14a e 14c e Quadro 1), a altura da seção é 45 cm, que consiste num h intermediário, dentre aqueles disponíveis para seleção na calculadora (para largura bw 25 cm, há h 40, 50 e 60 cm, Figura 10). Para armaduras positivas distribuídas em uma ou duas camadas, verificou-se que os TRFs obtidos pela calculadora para as diferentes alturas analisadas eram muito próximas. Porém, às vezes estavam ligeiramente a favor da segurança valores encontrados para alturas maiores e, outras, para menores.
Portanto, para dimensionar vigas com armaduras positivas em uma ou duas camadas e com alturas intermediárias via TRFVIG, deve-se: calcular os TRFs selecionando as alturas do intervalo correspondente à altura pretendida e considerar, a favor da segurança, o TRF final da viga igual ao menor resultado. Para a viga simplesmente apoiada b, calcularam-se TRFs para alturas iguais a 40 e 50 cm, resultando em 121 min para ambas (Figuras 15a e 16a).
Para armaduras negativas em uma ou duas camadas: após comparar valores de µ do banco de dados da calculadora, verificou-se que esses eram bem diferentes, considerando-se distribuições de armaduras em vigas com larguras iguais e alturas distintas (ou seja, o contrário do observado nas armaduras positivas). Entretanto, notou-se uma tendência consistente: quanto maior a altura h, maiores os TRFs ou, em outras palavras, menores os valores de µ (Figuras 7 e 12 esboçam curvas µ vs TRF, para melhor entendimento).
Figura 15
Resultados calculadora TRFVIG vs método gráfico para vigas simplesmente apoiadas (a) e vigas contínuas a (b), b (c) e c (d)
Figura 16
Resultados calculadora TRFVIG vs método tabular para vigas simplesmente apoiadas (a) e vigas contínuas a (b), b (c) e c (d)
Logo, assume-se uma viga de 19 x 70 cm com armadura negativa em uma ou duas camadas. Apesar dessa altura ser superior às analisadas para a largura de 19 cm (não disponível para seleção, vide Figura 10), a segurança estará atendida ao adotar o resultado da calculadora considerando h igual a 60 cm.
Outra situação particular: viga com armadura negativa de altura intermediária, dentre os valores de h disponíveis. Toma-se como exemplo a viga contínua a (Figuras 14b e 14c e Quadro 2), com redistribuição de momentos 2 (Quadro 3), em que h é 55 cm. Estará a favor da segurança o TRF encontrado pela seleção da altura que representa a opção imediatamente inferior à pretendida, i.e., 50 cm. Para tal h, TRF é 147 min (Figuras 15b e 16b), enquanto para h 60 cm seria igual a 167 min.
Para armaduras positivas ou negativas em duas camadas, deve-se estar atento ao rótulo associado ao campo “armadura por camada”: “Indica a armadura existente em cada camada, portanto, para armaduras dispostas em duas camadas, onde se lê 2ϕ10 (2f10), por exemplo, deve-se entender que são duas camadas com 2ϕ10 em cada uma das camadas. Assim, para duas camadas, 2ϕ10 significa, na verdade, armadura total igual a 4ϕ10 distribuídas em duas camadas com o mesmo número de barras.”
Na viga simplesmente apoiada c (Figuras 14a e 14c e Quadro 1), a área de aço da armadura positiva (As+) é equivalente a 4ϕ16 mm distribuídas em duas camadas. Nesse caso, seleciona-se “2” no campo “número de camadas”, escolhe-se “2f16” em “armadura por camada”. O relatório de resultados certificará ao usuário que a armadura total é igual a 4ϕ16 (As = 8,04 cm2).
Para o dimensionamento de vigas contínuas (Figuras 14b e 14c e Quadro 2), deve-se determinar os valores de TRF equivalentes aos trechos com armaduras positiva e negativa, compará-los e, para segurança, considerar como o resultado final de TRF da viga o menor valor encontrado.
Nas vigas simplesmente apoiadas b e d (Figura 16a) e em alguns casos de vigas contínuas (Figuras 16b a 16d), há dois resultados provenientes do método tabular. Esses são correspondentes a seções com somente uma camada de armadura e largura não superior ao bmín indicado nas colunas 3 e 2 do método tabular para dimensionamento de vigas da NBR 15200 (ABNT, 2012), sendo essas colunas referentes a vigas simplesmente apoiadas e contínuas, respectivamente. O valor de bmín a ser comparado com a largura da viga deve ser determinado em função do TRF.
Nessas situações, assume-se que há concentração de temperatura junto às bordas da face inferior das vigas, sendo necessário alterar o arranjo das armaduras, para afastar as barras de canto da face lateral do concreto exposta ao fogo. Se as alterações indicadas na NBR 15200 (ABNT, 2012) não forem efetuadas, para permanecer com valores estipulados no projeto, o TRF deve ser recalculado considerando c1 reduzido em 10 mm (Figura 1). Na Figura 16, “resultado 1” representa a consideração das alterações e “resultado 2” a decisão de manter o arranjo inicial.
A priori, realizaram-se comparações TRFVIG vs método gráfico, a fim de validar a eficácia da calculadora em reproduzir resultados provenientes do desenvolvimento do método gráfico discutido em Dimensionamento a temperaturas elevadas, que compõem seu banco de dados. Com base nos exemplos, os resultados obtidos via TRFVIG foram iguais ou muito próximos aos do método gráfico, vide Figura 15 e Tabelas 3 a 6 (nessas tabelas, os valores negativos indicam reduções do TRF em comparação aos resultados da calculadora). Na maioria dos casos, as diferenças foram iguais ou inferiores a 5,6%. A maior diferença, registrada na viga simplesmente apoiada a, foi igual a 11,5% (Figura 15a).
Tabela 3
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) de vigas simplesmente apoiadas, com comparações em relação à calculadora TRFVIG
Resultados
Viga a
Viga b
Viga c
Viga d
Calculadora TRFVIG (x) [min]
130
121
98
98
Método gráfico (y) [min]
115
120
90
90
Diferença x - y [min]
15
1
8
8
Desvio padrão s [min]
7,5
0,5
4
4
Relação y/x [adimensional]
0,885
0,992
0,918
0,918
Erro [%]
-11,5
-0,8
-8,2
-8,2
Método tabular - Resultado 1 (z) [min]
90
96
64,5
66,5
Diferença x - z [min]
40
25
33,5
31,5
Desvio padrão s [min]
20
12,5
16,75
15,75
Relação z/x [adimensional]
0,692
0,793
0,658
0,679
Erro [%]
-30,8
-20,7
-34,2
-32,1
Método tabular - Resultado 2 (w) [min]
-
82,5
-
56
Diferença x - w [min]
-
38,5
-
42
Desvio padrão s [min]
-
19,25
-
21
Relação w/x [adimensional]
-
0,682
-
0,571
Erro [%]
-
-31,8
-
-42,9
Tabela 4
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) da viga contínua a, com comparações em relação à calculadora TRFVIG
Resultados
Caso 1
Caso 2
Caso 3
Caso 4
Calculadora TRFVIG (x) [min]
130
147
157
154
Método gráfico (y) [min]
125
145
150
140
x - y [min]
5
2
7
14
Desvio padrão s [min]
2,5
1
3,5
7
Relação y/x [adimensional]
0,962
0,986
0,955
0,909
Erro [%]
-3,8
-1,4
-4,5
-9,1
Método tabular - Resultado 1 (z) [min]
150
150
150
150
x - z [min]
-20
-3
7
4
Desvio padrão s [min]
10
1,5
3,5
2
Relação z/x [adimensional]
1,154
1,020
0,955
0,974
Erro [%]
15,4
2
-4,5
-2,6
Método tabular - Resultado 2 (w) [min]
117,5
112,5
117,5
112,5
x - w [min]
12,5
34,5
39,5
41,5
Desvio padrão s [min]
6,25
17,25
19,75
20,75
Relação w/x [adimensional]
0,904
0,765
0,748
0,731
Erro [%]
-9,6
-23,5
-25,2
-26,9
Tabela 5
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) da viga contínua b, com comparações em relação à calculadora TRFVIG
Resultados
Caso 1
Caso 2
Caso 3
Caso 4
Calculadora TRFVIG (x) [min]
90
109
104
98
Método gráfico (y) [min]
85
105
100
95
x - y [min]
5
4
4
3
Desvio padrão s [min]
2,5
2
2
1,5
Relação y/x [adimensional]
0,944
0,963
0,962
0,969
Erro [%]
-5,6
-3,7
-3,8
-3,1
Calculadora TRFVIG (x) [min]
90
109
104
98
Método tabular - Resultado 1 (z) [min]
86
88
86
88
x - z [min]
4
21
18
10
Desvio padrão s [min]
2
10,5
9
5
Relação z/x [adimensional]
0,956
0,807
0,827
0,898
Erro [%]
-4,4
-19,3
-17,3
-10,2
Calculadora TRFVIG (x) [min]
90
109
104
98
Método tabular - Resultado 2 (w) [min]
75,5
78,5
75,5
78,5
x - w [min]
14,5
30,5
28,5
19,5
Desvio padrão s [min]
7,25
15,25
14,25
9,75
Relação w/x [adimensional]
0,839
0,720
0,726
0,801
Erro [%]
-16,1
-28
-27,4
-19,9
Tabela 6
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) da viga contínua c, com comparações em relação à calculadora TRFVIG
Resultados
Caso 1
Caso 2
Caso 3
Caso 4
Calculadora TRFVIG (x) [min]
162
180
180
180
Método gráfico (y) [min]
160
180
180
180
x - y [min]
2
0
0
0
Desvio padrão s [min]
1
0
0
0
Relação y/x [adimensional]
0,988
1,000
1,000
1,000
Erro [%]
-1,2
0
0
0
Calculadora TRFVIG (x) [min]
162
180
180
180
Método tabular - Resultado 1 (z) [min]
164
180
164
180
x - z [min]
-2
0
16
0
Desvio padrão s [min]
1
0
8
0
Relação z/x [adimensional]
1,012
1,000
0,911
1,000
Erro [%]
1,2
0
-8,9
0
Calculadora TRFVIG (x) [min]
162
180
180
180
Método tabular - Resultado 2 (w) [min]
125
-
125
-
x - w [min]
37
-
55
-
Desvio padrão s [min]
18,5
-
27,5
-
Relação w/x [adimensional]
0,772
-
0,694
-
Erro [%]
-22,8
-
-30,6
-
Essas variações eram esperadas, pois todos os resultados das análises numéricas foram utilizados para compor o banco de dados da calculadora, enquanto no método gráfico, escolheram-se os resultados mais representativos e seguros, que poderiam eventualmente conduzir a menores TRFs. De fato, quando existentes, as diferenças apontaram tempos mais elevados nos valores obtidos pela ferramenta computacional. Por isso, a calculadora pode apresentar soluções até mais econômicas que o método gráfico. TRFs maiores reduzem o volume de concreto necessário e/ou a quantidade de armadura, conduzindo a menores custos de construção.
Adicionalmente, realizaram-se comparações TRFVIG vs método tabular, abordado em Considerações iniciais (Figura 16 e Tabelas 3 a 6). Observou-se que a calculadora resultou em soluções mais econômicas para vigas simplesmente apoiadas, quando comparada ao método tabular. As diferenças variaram de 20,7 a 42,9% (em relação ao resultado 1 do método tabular para viga b e resultado 2 para viga d).
Neste artigo, os resultados mais críticos do método tabular, para vigas simplesmente apoiadas e contínuas, provêm da decisão de manter o arranjo inicial da armadura para situações de concentração de temperaturas. Na viga simplesmente apoiada d, a diferença foi a mais marcante, 42,9%. Na viga contínua c, caso de redistribuição 3, a diferença chegou a 30,6%. Resultados críticos se referem a menores TRFs, que podem ser insuficientes para atender a requisitos de projeto.
Nas vigas contínuas, verificou-se que a redistribuição de momentos à temperatura ambiente, em incêndio, ou a aplicação de ambas, melhora o TRF. Tomando-se os resultados mais críticos do método tabular, a calculadora se mostrou a favor da economia novamente. Contudo, não houve uma regra quanto à melhor forma de redistribuir momentos. µ trabalha com momentos relativos, sendo complicado estabelecer qual combinação conduz a um maior aproveitamento. Sugere-se avaliar diferentes combinações para encontrar o resultado mais favorável.
Riva e Franssen (2008) também compararam valores de TRF para diferentes modelos de vigas contínuas. No entanto, confrontaram ao método tabular do EN 1992-1-2 (ECS, 2004) os resultados obtidos via programa de computador Abaqus (Abaqus, versão de 2006). Nas análises numéricas, adotaram métodos avançados, considerando fenômenos como fissuração do concreto e efeitos das restrições às deformações térmicas. Os autores também observaram que o método tabular pode fornecer resultados mais conservadores.
Contudo, devido ao grande número de variáveis, a comparação entre a calculadora TRFVIG e o método tabular não é imediata. Portanto, pela simplicidade, recomenda-se o método tabular como primeira opção para o dimensionamento de vigas. Se as exigências em relação ao TRF não forem atendidas, pode-se então recorrer ao uso da calculadora. É importante esclarecer que tanto o método gráfico quanto sua versão computacional, a calculadora TRFVIG, foram criados como alternativas às tabelas e não para substituí-las.
Conclusões
Esta pesquisa apresenta um programa de computador que calcula o tempo de resistência ao fogo (TRF) de vigas de concreto armado, oferecendo mais de 2300 alternativas de seção transversal/arranjo de armaduras para cada tempo requerido de resistência ao fogo (TRRF). Seus resultados são provenientes de um método de dimensionamento alternativo, que segue as diretrizes da NBR 15200 (ABNT, 2012) para simulações termestruturais via método dos elementos finitos (MEF).
O método de dimensionamento alternativo foi desenvolvido com base em um estudo numérico paramétrico e sua precisão foi confirmada pela validação de sua principal variável, o momento fletor resistente da seção de uma viga aquecida (MRd,fi). Conforme demonstrado em Albuquerque, Silva e Rodrigues (2022), os resultados se mostraram similares àqueles procedentes de diferentes métodos simplificados, propostos pelas normas brasileira NBR 15200 (ABNT, 2012) e europeia EN 1992-1-2 (ECS, 2004), e também de um método mais avançado (Klein Júnior, 2011).
A calculadora TRFVIG considera o equilíbrio de forças sem impor temperatura limite nas armaduras, podendo eventualmente indicar soluções mais econômicas que o método tabular da norma brasileira. Também permite incorporar redistribuições de momentos fletores solicitantes, que otimizam o TRF.
É executável de modo independente em computadores convencionais com Windows 7+, tornando-se uma ferramenta útil e inclusiva. Assim, pode futuramente ser integrada como calculadora auxiliar em programas de análise estrutural. Seu uso é intuitivo, permitindo que os usuários insiram dados simples e analisem resultados facilmente.
A calculadora pode ser aplicada para dimensionar vigas sob lajes (seções T) com espessuras mínimas de 5 cm, concreto com fck entre 25 e 50 MPa, aço de fyk igual a 500 MPa, estribos com diâmetro mínimo de 5 mm e exposição ao fogo, conforme incêndio-padrão ISO 834 (ISO, 1999), nas três faces das vigas (laterais e inferior) e sob as lajes.
Testes de funcionamento e exemplos de aplicação comprovaram a precisão da calculadora, uma vez que mostraram resultados iguais ou muito próximos aos do método de dimensionamento que a originou, validando as hipóteses de sua implementação. Logo, poderá embasar trabalhos futuros, facilitando o aproveitamento de soluções decorrentes de pesquisas acadêmicas na execução de projetos.
Programas de computador específicos para dimensionamento prático em incêndio ainda não são usuais no Brasil e no exterior. Sendo assim, a calculadora TRFVIG representa uma inovação que contribui para avanços na tecnologia computacional dessa área.
O conceito proposto, de desenvolver métodos computacionais fundamentados em análises mais avançadas, implementando-os de modo acessível aos projetistas, pode oferecer uma nova perspectiva sobre o dimensionamento de estruturas resistentes ao fogo.
1
Klein Júnior (2011) e Padre et al. (2019) desenvolveram originalmente ferramentas para avaliar pilares. Contudo, essas foram adaptadas para a análise de vigas, conforme demonstrado em Albuquerque (2012) e Padre et al. (2019), respectivamente.
2
Fenômeno responsável pela redução da capacidade do concreto submetido à situação de incêndio, devido à perda de sua área resistente e, sobretudo, pela possível exposição da armadura ao fogo.
Agradecimentos
Os autores agradecem aos Engenheiros Alio Ernesto Kimura e Johnny Aparecido Fontana Bruno, pela contribuição no desenvolvimento da calculadora TRFVIG, à Agência USP de Inovação (AUSPIN), pelo apoio no registro desse programa de computador junto ao Instituto Nacional da Propriedade Industrial (INPI), à Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP), pelo financiamento do projeto nº 2018/14735-6, e ao Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq).
Referências
ABAQUS. Finite element analysis. Pawtucket: Hibbert, Karlsson & Sorenson, 2008.
ABAQUS
Finite element analysis
Pawtucket
Hibbert, Karlsson & Sorenson
2008
Albrifkani, S.; Wang, Y. C. Explicit modelling of large deflection behaviour of restrained reinforced concrete beams in fire. Engineering Structures, v. 121, n. 15, p. 97-119, 2016.
Albrifkani
S
Wang
Y. C
Explicit modelling of large deflection behaviour of restrained reinforced concrete beams in fire
Engineering Structures
121
15
97
119
2016
ALBUQUERQUE, G. B. M. L. Análise numérico-experimental de vigas de concreto armado com restrições axial e rotacional em situação de incêndio. São Paulo, 2018. 413 f. Tese (Doutorado em Engenharia de Estruturas e Doutoramento em Engenharia de Segurança ao Incêndio) - Escola Politécnica, Universidade de São Paulo, São Paulo, e Faculdade de Ciências e Tecnologia, Universidade de Coimbra, Coimbra, 2018.
ALBUQUERQUE
G. B. M. L
Análise numérico-experimental de vigas de concreto armado com restrições axial e rotacional em situação de incêndio
São Paulo
2018
413 f
Tese (Doutorado em Engenharia de Estruturas e Doutoramento em Engenharia de Segurança ao Incêndio) - Escola Politécnica
Universidade de São Paulo
São Paulo
Faculdade de Ciências e Tecnologia, Universidade de Coimbra
Coimbra
ALBUQUERQUE, G. B. M. L. Dimensionamento de vigas de concreto armado em situação de incêndio. São Paulo, 2012. 245 f. Dissertação (Mestrado em Engenharia de Estruturas) - Escola Politécnica, Universidade de São Paulo, São Paulo, 2012.
ALBUQUERQUE
G. B. M. L
Dimensionamento de vigas de concreto armado em situação de incêndio
São Paulo
2012
245 f
Dissertação (Mestrado em Engenharia de Estruturas) - Escola Politécnica
Universidade de São Paulo
São Paulo
ALBUQUERQUE, G. B. M. L. Reinforced concrete beams fire design: standardized and alternative methods. Saarbrücken: LAMBERT Academic Publishing, 2014.
ALBUQUERQUE
G. B. M. L
Reinforced concrete beams fire design: standardized and alternative methods
Saarbrücken
LAMBERT Academic Publishing
2014
Albuquerque, G. B. M. L.; Silva, V. P.; Rodrigues, J. P. C. A graphical method for fire design of reinforced concrete beams. Fire Technology, v. 58, n. 2, p. 737-775, 2022.
Albuquerque
G. B. M. L
Silva
V. P
Rodrigues
J. P. C
A graphical method for fire design of reinforced concrete beams
Fire Technology
58
2
737
775
2022
ALBUQUERQUE, G. B. M. L. et al. TRFVIG - Cálculo do tempo de resistência ao fogo (TRF) de vigas de concreto armado. Titular: Universidade de São Paulo. Instituição de registro: Instituto Nacional da Propriedade Industrial. BR512024000239-1. Depósito: 24 jan. 2024. Concessão: 30 jan. 2024.
ALBUQUERQUE
G. B. M. L
TRFVIG - Cálculo do tempo de resistência ao fogo (TRF) de vigas de concreto armado
Universidade de São Paulo
Instituição de registro: Instituto Nacional da Propriedade Industrial
BR512024000239-1
Depósito: 24 jan. 2024
Concessão: 30 jan. 2024
2024
Albuquerque, G. L. et al. Behavior of thermally restrained RC beams in case of fire. Engineering Structures, v. 174, p. 407-417, 2018.
Albuquerque
G. L.
Behavior of thermally restrained RC beams in case of fire
Engineering Structures
174
407
417
2018
Anderberg, Y. Structural fire design for composite slabs and beams. Malmö: Fire Safety Design, 2001.
Anderberg
Y
Structural fire design for composite slabs and beams
Malmö
Fire Safety Design
2001
ANSYS INC. Ansys realese 9.0: documentation. 2004.
ANSYS INC.
Ansys realese 9.0
documentation
2004
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 14432: exigências de resistência ao fogo de elementos construtivos de edificações: procedimento. Rio de Janeiro, 2001.
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS
NBR 14432: exigências de resistência ao fogo de elementos construtivos de edificações: procedimento
Rio de Janeiro
2001
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15200: projeto de estruturas de concreto em situação de incêndio. Rio de Janeiro, 2012.
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS
NBR 15200: projeto de estruturas de concreto em situação de incêndio
Rio de Janeiro
2012
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 6118: projeto de estruturas de concreto: procedimento. Rio de Janeiro, 2007.
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS
NBR 6118: projeto de estruturas de concreto: procedimento
Rio de Janeiro
2007
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 6118: projeto de estruturas de concreto. Rio de Janeiro, 2023.
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS
NBR 6118: projeto de estruturas de concreto
Rio de Janeiro
2023
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 8681: ações e segurança nas estruturas. Rio de Janeiro, 2004.
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS
NBR 8681: ações e segurança nas estruturas
Rio de Janeiro
2004
BERNHART, D. The effect of support conditions on the fire resistance of a reinforced concrete beam. 2004. Christchurch, 147 f. Thesis (Diplom-Bauingenieurin) - University of Karlsruhe, Karlsruhe; University of Canterbury, Christchurch, 2004.
BERNHART
D
The effect of support conditions on the fire resistance of a reinforced concrete beam
2004
Christchurch
147 f
Thesis (Diplom-Bauingenieurin)
University of Karlsruhe
Karlsruhe
University of Canterbury
Christchurch
Biondini, F.; Nero, A. Nonlinear analysis of concrete structures exposed to fire. In: INTERNATIONAL CONGRESS FÉDÉRATION INTERNATIONALE DU BÉTON, 2., Naples, 2006. Proceedings […] Naples: CEB-FIP, 2006.
Biondini
F
Nero
A
Nonlinear analysis of concrete structures exposed to fire
INTERNATIONAL CONGRESS FÉDÉRATION INTERNATIONALE DU BÉTON
2
Naples
2006
Proceedings
Naples
CEB-FIP
2006
Boulvard, S.; Pham, D. T.; Bleyer, J. Evaluation of the shear capacity of RC beams in fire conditions, Engineering Structures, v. 316, 2024.
Boulvard
S.
Pham
D. T.
Bleyer
J.
Evaluation of the shear capacity of RC beams in fire conditions
Engineering Structures
316
2024
BRASIL. Lei nº 13.425, de 30 de março 2017. Diretrizes gerais sobre medidas de prevenção e combate a incêndio e a desastres em estabelecimentos, edificações e áreas de reunião de público. Diário Oficial da União, Brasília, 2017.
BRASIL
Lei nº 13.425, de 30 de março 2017
Diretrizes gerais sobre medidas de prevenção e combate a incêndio e a desastres em estabelecimentos, edificações e áreas de reunião de público
Diário Oficial da União
Brasília
2017
BRASIL. Lei nº 8.078, de 11 de setembro de 1990. Código de defesa do consumidor. Diário Oficial da União, Brasília, 1990.
BRASIL
Lei nº 8.078, de 11 de setembro de 1990
Código de defesa do consumidor
Diário Oficial da União
Brasília
1990
Bratina, S. et al. Non-linear fire-resistance analysis of reinforced concrete beams. Structural Engineering and Mechanics, v. 16, n. 6, p. 695-712, 2003.
Bratina
S.
Non-linear fire-resistance analysis of reinforced concrete beams
Structural Engineering and Mechanics
16
6
695
712
2003
CALDAS, R. B. Análise numérica de estruturas de aço, concreto e mistas em situação de incêndio. Belo Horizonte, 2008. 226 f. Tese (Doutorado em Engenharia de Estruturas) - Escola de Engenharia, Universidade Federal de Minas Gerais, Belo Horizonte, 2008.
CALDAS
R. B
Análise numérica de estruturas de aço, concreto e mistas em situação de incêndio
Belo Horizonte
2008
226 f
Tese (Doutorado em Engenharia de Estruturas) - Escola de Engenharia
Universidade Federal de Minas Gerais
Belo Horizonte
CASTRO, G. G. S. Um método geral de cálculo para verificação de estruturas de concreto em situação de incêndio. Belo Horizonte, 2005. 97 f. Dissertação (Mestrado em Engenharia de Estruturas) - Escola de Engenharia, Universidade Federal de Minas Gerais, Belo Horizonte, 2005.
CASTRO
G. G. S
Um método geral de cálculo para verificação de estruturas de concreto em situação de incêndio
Belo Horizonte
2005
97 f
Dissertação (Mestrado em Engenharia de Estruturas) - Escola de Engenharia
Universidade Federal de Minas Gerais
Belo Horizonte
CHOI, E. G.; SHIN, Y. S. The structural behavior and simplified thermal analysis of normal-strength and high-strength concrete beams under fire. Engineering Structures, v. 33, n. 4, p. 1123-1132, 2011.
CHOI
E. G.
SHIN
Y. S.
The structural behavior and simplified thermal analysis of normal-strength and high-strength concrete beams under fire
Engineering Structures
33
4
1123
1132
2011
CHYTHANYA, M. Finite element analysis on the effect of fire for specified duration, on a reinforced concrete beam with varied boundary conditions. Florida, 2009. 77 f. Master’s Thesis - College of Engineering, Florida State University, Florida, 2008.
CHYTHANYA
M
Finite element analysis on the effect of fire for specified duration, on a reinforced concrete beam with varied boundary conditions
Florida
2009
77 f
Master’s Thesis - College of Engineering
Florida State University
Florida
Coelho, T. A. P. Avaliação da confiabilidade de seções de vigas de concreto armado em situação de incêndio. Belo Horizonte, 2018. 103 f. Dissertação (Mestrado em Engenharia de Estruturas) - Escola de Engenharia, Universidade Federal de Minas Gerais, Belo Horizonte, 2018.
Coelho
T. A. P
Avaliação da confiabilidade de seções de vigas de concreto armado em situação de incêndio
Belo Horizonte
2018
103 f
Dissertação (Mestrado em Engenharia de Estruturas) - Escola de Engenharia
Universidade Federal de Minas Gerais
Belo Horizonte
COSTA, C. N. Dimensionamento de elementos de concreto armado em situação de incêndio. São Paulo, 2008. 724 f. Tese (Doutorado em Engenharia de Estruturas) - Escola Politécnica, Universidade de São Paulo, São Paulo, 2008.
COSTA
C. N
Dimensionamento de elementos de concreto armado em situação de incêndio
São Paulo
2008
724 f
Tese (Doutorado em Engenharia de Estruturas) - Escola Politécnica
Universidade de São Paulo
São Paulo
Cvetkovska, M.; Todorov, K.; Lazarov, L. Axial restraint effects on fire resistance of statically indeterminate RC beams. Journal of Structural Fire Engineering, v. 4, n. 1, p. 47-58, 2013.
Cvetkovska
M
Todorov
K
Lazarov
L
Axial restraint effects on fire resistance of statically indeterminate RC beams
Journal of Structural Fire Engineering
4
1
47
58
2013
DALFRÉ, G. M.; SARTI JÚNIOR, L. A.; ARAÚJO, C. J. R. V. Protocolo acelerado de degradação do sistema de reforço EBR-CFRP aplicado em vigas de concreto armado. Ambiente Construído, Porto Alegre, v. 21, n. 3, p. 273-293, jul./set. 2021.
DALFRÉ
G. M.
SARTI
L. A.
JÚNIOR
ARAÚJO
C. J. R. V.
Protocolo acelerado de degradação do sistema de reforço EBR-CFRP aplicado em vigas de concreto armado
Ambiente Construído
Porto Alegre
21
3
273
293
jul./set
2021
DEBELLA, L. C. et al. Análise quantitativa dos mecanismos de transferência de força cortante de vigas de concreto armado reforçado com fibras de aço. Ambiente Construído, Porto Alegre, v. 24, e131653, jan./dez. 2024.
DEBELLA
L. C
Análise quantitativa dos mecanismos de transferência de força cortante de vigas de concreto armado reforçado com fibras de aço
Ambiente Construído
Porto Alegre
24
e131653
131653
131653
jan./dez
2024
DIANA FEA. User’s manual: release 10.1. Delft: DIANA FEA BV, 2016. 13 v.
DIANA FEA
User’s manual: release 10.1
Delft
DIANA FEA BV
2016
13 v
DOTREPPE, J. C.; FRANSSEN, J. M. The use of numerical models for the fire analysis of reinforced concrete and composite structures. Engineering Analysis, v. 2, n. 2, p. 67-74, 1985.
DOTREPPE
J. C.
FRANSSEN
J. M.
The use of numerical models for the fire analysis of reinforced concrete and composite structures
Engineering Analysis
2
2
67
74
1985
DWAIKAT, M. B. Flexural response of reinforced concrete beams exposed to fire. East Lansing, 2009. 369 f. PhD Dissertation - Michigan State University, East Lansing, 2009.
DWAIKAT
M. B.
Flexural response of reinforced concrete beams exposed to fire
East Lansing
2009
369 f.
PhD Dissertation
Michigan State University
East Lansing
Dwaikat, M. B.; Kodur, V. K. R. A numerical approach for modeling the fire induced restraint effects in reinforced concrete beams. Fire Safety Journal, v. 43, n. 4, p. 291–307, 2008.
Dwaikat
M. B.
Kodur
V. K. R.
A numerical approach for modeling the fire induced restraint effects in reinforced concrete beams
Fire Safety Journal
43
4
291
307
2008
Ehm, H. Ein beitrag zur rechnerischen bemessung von brandbeanspruchten balkenartigen stahlbetonbauteilen. Braunschweig, 1967. 148 f. Dissertation - Technische Universität Braunschweig, Braunschweig, 1967.
Ehm
H.
Ein beitrag zur rechnerischen bemessung von brandbeanspruchten balkenartigen stahlbetonbauteilen
Braunschweig
1967
148 f
Dissertation
Technische Universität Braunschweig
Braunschweig
Elshorbagi, M.; Al Hamaydeh, M. Simulation of RC beams during fire events using a nonlinear numerical fully coupled thermal-stress analysis. Fire, v. 6, n. 57, 2023.
Elshorbagi
M
Al Hamaydeh
M
Simulation of RC beams during fire events using a nonlinear numerical fully coupled thermal-stress analysis
Fire
6
57
2023
EUROPEAN COMMITTEE FOR STANDARDIZATION. EN 1992-1-2: eurocode 2: design of concrete structures: part 1.2: general rules: structural fire design. Brussels, 2004.
EUROPEAN COMMITTEE FOR STANDARDIZATION
EN 1992-1-2
eurocode 2: design of concrete structures: part 1.2: general rules: structural fire design
Brussels
2004
FIGUEIREDO JÚNIOR, F. P. Simulação via método dos elementos finitos da distribuição de temperatura em estruturas metálicas e mistas em caso de incêndio. Belo Horizonte, 2002. 116 f. Dissertação (Mestrado em Engenharia de Estruturas) - Escola de Engenharia, Universidade Federal de Minas Gerais, Belo Horizonte, 2002.
FIGUEIREDO
F. P.
JÚNIOR
Simulação via método dos elementos finitos da distribuição de temperatura em estruturas metálicas e mistas em caso de incêndio
Belo Horizonte
2002
116 f.
Dissertação (Mestrado em Engenharia de Estruturas) - Escola de Engenharia
Universidade Federal de Minas Gerais
Belo Horizonte
FINE CIVIL ENGINEERING. Concrete Fire - FIN EC. 2016. Disponível em: https://geotechpedia.com/Software/Show/732/Concrete-Fire-FIN-EC. Acesso em: 12 abr. 2023.
FINE CIVIL ENGINEERING
Concrete Fire - FIN EC
2016
Disponível em: https://geotechpedia.com/Software/Show/732/Concrete-Fire-FIN-EC
12 abr. 2023
FIRE SAFETY DESIGN. TCD 5.0 User’s manual. Lund: Fire Safety Design AB, 2007.
FIRE SAFETY DESIGN
TCD 5.0 User’s manual
Lund
Fire Safety Design AB
2007
FRANSSEN, J. M. SAFIR: a thermal/structural program for modeling structures under fire. Engineering Journal, v. 42, n. 3, p. 143-158, 2005.
FRANSSEN
J. M
SAFIR: a thermal/structural program for modeling structures under fire
Engineering Journal
42
3
143
158
2005
FRANSSEN, J. M.; KODUR, V. K. R.; MASON, J. Elements of theory for SAFIR 2002: a computer program for analysis of structures submitted to the fire. Liège: Department Mécanique des Matériaux & Structures - University of Liège, 2002.
FRANSSEN
J. M.
KODUR
V. K. R.
MASON
J.
Elements of theory for SAFIR 2002: a computer program for analysis of structures submitted to the fire
Liège
Department Mécanique des Matériaux & Structures - University of Liège
2002
FREITAG, J. K. The fireproofing of steel structures. New York: John Wiley & Sons, 1899.
FREITAG
J. K.
The fireproofing of steel structures
New York
John Wiley & Sons
1899
FREITAS, M. R.; RUSCHEL, R. C. Validação de aplicativo comercial visando à incorporação da realidade aumentada a um modelo de avaliação pós-ocupação. Ambiente Construído, Porto Alegre, v. 15, n. 2, p. 97-112, abr./jun. 2015.
FREITAS
M. R.
RUSCHEL
R. C.
Validação de aplicativo comercial visando à incorporação da realidade aumentada a um modelo de avaliação pós-ocupação
Ambiente Construído
Porto Alegre
15
2
97
112
abr./jun
2015
Gao, W. Y. et al. Finite element modelling of reinforced concrete beams exposed to fire. Engineering Structures, v. 52, p. 488-501, 2013.
Gao
W. Y.
Finite element modelling of reinforced concrete beams exposed to fire
Engineering Structures
52
488
501
2013
GAO, W. Y.; DAI, J. G.; TENG, J. G. Fire resistance of RC beams under design fire exposure. Magazine of Concrete Research, v. 69, n. 8, p. 402-423, 2017.
GAO
W. Y
DAI
J. G
TENG
J. G
Fire resistance of RC beams under design fire exposure
Magazine of Concrete Research
69
8
402
423
2017
GERNAY, T. et al. Numerical analysis of the effects of fire with cooling phase on reinforced concrete members, Engineering Structures, v. 293, 2023.
GERNAY
T.
Numerical analysis of the effects of fire with cooling phase on reinforced concrete members
Engineering Structures
293
2023
GONÇALVES, M. J. C. R. Comportamento ao fogo de elementos estruturais de betão: análise numérica e metodologia. Porto, 2007. 791 f. Tese (Doutoramento em Engenharia Civil) - Faculdade de Engenharia, Universidade do Porto, Porto, 2007.
GONÇALVES
M. J. C. R
Comportamento ao fogo de elementos estruturais de betão: análise numérica e metodologia
Porto
2007
791 f
Tese (Doutoramento em Engenharia Civil) - Faculdade de Engenharia
Universidade do Porto
Porto
GONÇALVES, M. J. C. R.; RODRIGUES, J. P. C. Ultimate bending moment capacity of reinforced concrete beam sections at high temperatures. In: INTERNATIONAL WORKSHOP ‘‘FIRE DESIGN OF CONCRETE STRUCTURES: FROM MATERIALS MODELLING TO STRUCTURAL PERFORMANCE’, Coimbra, 2007. Proceedings […] Coimbra: Department of Civil Engineering, University of Coimbra, 2007.
GONÇALVES
M. J. C. R.
RODRIGUES
J. P. C.
Ultimate bending moment capacity of reinforced concrete beam sections at high temperatures
INTERNATIONAL WORKSHOP ‘‘FIRE DESIGN OF CONCRETE STRUCTURES: FROM MATERIALS MODELLING TO STRUCTURAL PERFORMANCE
Coimbra
2007
Proceedings
Coimbra
Department of Civil Engineering, University of Coimbra
2007
GUO, Z.; SHI, X. Experiment and calculation of reinforced concrete at elevated temperatures. Waltham: Butterworth-Heinemann, 2011.
GUO
Z
SHI
X
Experiment and calculation of reinforced concrete at elevated temperatures
Waltham
Butterworth-Heinemann
2011
HUANG, Z.; BURGESS, I. W.; PLANK, R. J. A non-linear beam-column element for 3D modelling of general cross-sections in fire. Sheffield: University of Sheffield, 2003. (Research Report n. DCSE/03/F/1).
HUANG
Z
BURGESS
I. W
PLANK
R. J
A non-linear beam-column element for 3D modelling of general cross-sections in fire
Sheffield
University of Sheffield
2003
Research Report n. DCSE/03/F/1
INNOVATION NETWORK & OPEN INNOVATION REFERENT. Beafire: simulating fire resistance of reinforced concrete beams. Disponível em: https://www.innoget.com/technology-offers/7692/beafire-simulating-fire-resistance-of-reinforced-concrete-beams. Acesso em: 12 abr. 2023.
INNOVATION NETWORK & OPEN INNOVATION REFERENT
Beafire: simulating fire resistance of reinforced concrete beams
Disponível em: https://www.innoget.com/technology-offers/7692/beafire-simulating-fire-resistance-of-reinforced-concrete-beams
12 abr. 2023
2023
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. ISO 834-1: fire-resistance tests: elements of building construction: part 1: general requirements for fire resistance testing. Geneva, 1999.
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION
ISO 834-1
fire-resistance tests: elements of building construction: part 1: general requirements for fire resistance testing
Geneva
1999
Kang, S. W.; Hong, S. G. Analytical method for the behaviour of a reinforced concrete flexural member at elevated temperatures. Fire and Materials, v. 28 n. 2-4, p. 227-235, 2004.
Kang
S. W
Hong
S. G
Analytical method for the behaviour of a reinforced concrete flexural member at elevated temperatures
Fire and Materials
28
2-4
227
235
2004
KIRCHHOF, L. D. Estudo teórico-experimental da influência do teor de umidade no fenômeno de spalling explosivo em concretos expostos a elevadas temperaturas. Porto Alegre, 2010. 237 f. Tese (Doutorado em Engenharia de Estruturas) - Escola de Engenharia, Universidade Federal do Rio Grande do Sul, Porto Alegre, 2010.
KIRCHHOF
L. D
Estudo teórico-experimental da influência do teor de umidade no fenômeno de spalling explosivo em concretos expostos a elevadas temperaturas
Porto Alegre
2010
237 f
Tese (Doutorado em Engenharia de Estruturas) - Escola de Engenharia
Universidade Federal do Rio Grande do Sul
Porto Alegre
KLEIN JÚNIOR, O. Pilares de concreto armado em situação de incêndio submetidos à flexão normal composta. São Paulo, 2011. 208 f. Dissertação (Mestrado em Engenharia de Estruturas) - Escola Politécnica, Universidade de São Paulo, São Paulo, 2011.
KLEIN
O
JÚNIOR
Pilares de concreto armado em situação de incêndio submetidos à flexão normal composta
São Paulo
2011
208 f
Dissertação (Mestrado em Engenharia de Estruturas) - Escola Politécnica
Universidade de São Paulo
São Paulo
Kodur, V. K. R.; Agrawal, A. Effect of temperature induced bond degradation on fire response of reinforced concrete beams. Engineering Structures, v. 110, p. 98-109, 2017.
Kodur
V. K. R
Agrawal
A
Effect of temperature induced bond degradation on fire response of reinforced concrete beams
Engineering Structures
110
98
109
2017
KODUR, V. K. R.; DWAIKAT, M. B. A numerical model for predicting the fire resistance of reinforced concrete beams. Cement & Concrete Composites, v. 30, n. 5, p. 431-443, 2008b.
KODUR
V. K. R
DWAIKAT
M. B
A numerical model for predicting the fire resistance of reinforced concrete beams
Cement & Concrete Composites
30
5
431
443
2008b
Kodur, V. K. R.; Dwaikat, M. B. Design equation for predicting fire resistance of reinforced concrete beams. Engineering Structures, v. 33, n. 2, p. 602-614, 2011.
Kodur
V. K. R
Dwaikat
M. B
Design equation for predicting fire resistance of reinforced concrete beams
Engineering Structures
33
2
602
614
2011
KODUR, V. K. R.; DWAIKAT, M. B. Flexural response of reinforced concrete beams exposed to fire. Structural Concrete, v. 9, n. 1, p. 45-54, 2008a.
KODUR
V. K. R
DWAIKAT
M. B
Flexural response of reinforced concrete beams exposed to fire
Structural Concrete
9
1
45
54
2008a
Liao, F.; Huang, Z. An extended finite element model for modelling localised fracture of reinforced concrete beams in fire. Computers and Structures, v. 152, p. 11-26, 2015.
Liao
F
Huang
Z
An extended finite element model for modelling localised fracture of reinforced concrete beams in fire
Computers and Structures
152
11
26
2015
Lin, T. D.; Ellingwood, B.; Piet, O. Flexural and shear behavior of reinforced concrete beams during fire tests. Skokie: Portland Cement Association, 1988. (Research and Development Bulletin RD091T).
Lin
T. D
Ellingwood
B
Piet
O.
Flexural and shear behavior of reinforced concrete beams during fire tests
Skokie
Portland Cement Association
1988
Research and Development Bulletin RD091T
LIN, T. D.; GUSTAFERRO, A. H.; ABRAMS, M. S. Fire endurance of continuous reinforced concrete beams. Skokie: Portland Cement Association, 1981. (Research and Development Bulletin RD072.01B).
LIN
T. D.
GUSTAFERRO
A. H.
ABRAMS
M. S.
Fire endurance of continuous reinforced concrete beams
Skokie
Portland Cement Association
1981
Research and Development Bulletin RD072.01B
LIU, C. et al. Analysis and prediction methods for the static properties of reinforced concrete beams under fire. Structures, v. 47, p. 2319-2330, 2023.
LIU
C
Analysis and prediction methods for the static properties of reinforced concrete beams under fire
Structures
47
2319
2330
2023
MATHWORKS. MATLAB® 7: getting started guide. Natick, 2009.
MATHWORKS
MATLAB® 7: getting started guide
Natick
2009
Maximiano, D. P. Análise numérica avançada de estruturas de aço e de concreto armado em situação de incêndio. Ouro Preto, 2018. 197 f. Tese (Doutorado em Engenharia Civil) - Universidade Federal de Ouro Preto, Ouro Preto, 2018.
Maximiano
D. P
Análise numérica avançada de estruturas de aço e de concreto armado em situação de incêndio
Ouro Preto
2018
197 f
Tese (Doutorado em Engenharia Civil)
Universidade Federal de Ouro Preto
Ouro Preto
MICROSOFT OFFICE. Manual do Microsoft Office Excel 2007. 2006.
MICROSOFT OFFICE
Manual do Microsoft Office Excel 2007
2006
MIRAVAL, D. O. Análise não-linear de temperaturas para verificação da resistência de estruturas de concreto armado em situação de incêndio. Vitória, 2009. 119 f. Dissertação (Mestrado em Engenharia de Estruturas) - Centro Tecnológico, Universidade Federal de Espírito Santo, Vitória, 2009.
MIRAVAL
D. O
Análise não-linear de temperaturas para verificação da resistência de estruturas de concreto armado em situação de incêndio
Vitória
2009
119 f
Dissertação (Mestrado em Engenharia de Estruturas) - Centro Tecnológico
Universidade Federal de Espírito Santo
Vitória
MÖRSCH, E. Teoría y práctica del hormigón armado. Barcelona: Editorial Gustavo Gili, 1948.
MÖRSCH
E.
Teoría y práctica del hormigón armado
Barcelona
Editorial Gustavo Gili
1948
PADRE, E. P. G. et al. Algoritmo computacional para verificação de seções de concreto armado em situação de incêndio. Revista Ibracon de Estruturas e Materiais, v. 12, n. 4, p. 932-955, 2019.
PADRE
E. P. G
Algoritmo computacional para verificação de seções de concreto armado em situação de incêndio
Revista Ibracon de Estruturas e Materiais
12
4
932
955
2019
Pereira, E. et al. Physical, mechanical, and microstructural changes in concretes subjected to slow and fast cooling in a fire situation simulation. Ambiente Construído, Porto Alegre, v. 24, e133620, jan./dez. 2024.
Pereira
E.
Physical, mechanical, and microstructural changes in concretes subjected to slow and fast cooling in a fire situation simulation
Ambiente Construído
Porto Alegre
24
e133620
jan./dez
2024
Pereira, R. G. S. et al. Avaliação da resistência mecânica de vigas em concreto armado após o incêndio, Revista ALCONPAT, v. 9, n. 1, p. 93–105, 2018.
Pereira
R. G. S
Avaliação da resistência mecânica de vigas em concreto armado após o incêndio
Revista ALCONPAT
9
1
93
105
2018
PIERIN, I.; SILVA, V. P.; LA ROVERE, H. L. Análise térmica de estruturas bidimensionais em situação de incêndio. Revista Ibracon de Estruturas e Materiais, v. 8, n. 1, p. 25-48, 2015.
PIERIN
I
SILVA
V. P
LA ROVERE
H. L
Análise térmica de estruturas bidimensionais em situação de incêndio
Revista Ibracon de Estruturas e Materiais
8
1
25
48
2015
Pires, R. M. Análise de confiabilidade de vigas de concreto armado em situação de incêndio. Porto Alegre, 2023. 171 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal do Rio Grande do Sul, Porto Alegre, 2023.
Pires
R. M
Análise de confiabilidade de vigas de concreto armado em situação de incêndio
Porto Alegre
2023
171 f
Dissertação (Mestrado em Engenharia Civil)
Universidade Federal do Rio Grande do Sul
Porto Alegre
Reddy, D. V. et al. Size effect on fire resistance of structural concrete. Engineering Structures, v. 99, p. 468-478, 2015.
Reddy
D. V.
Size effect on fire resistance of structural concrete
Engineering Structures
99
468
478
2015
RIBEIRO, J. C. L. Simulação via método dos elementos finitos da distribuição tridimensional de temperatura em estruturas em situação de incêndio. Belo Horizonte, 2004. 178 f. Dissertação (Mestrado em Engenharia de Estruturas) - Escola de Engenharia, Universidade Federal de Minas Gerais, Belo Horizonte, 2004.
RIBEIRO
J. C. L
Simulação via método dos elementos finitos da distribuição tridimensional de temperatura em estruturas em situação de incêndio
Belo Horizonte
2004
178 f
Dissertação (Mestrado em Engenharia de Estruturas) - Escola de Engenharia
Universidade Federal de Minas Gerais
Belo Horizonte
RIGBERTH, J. Simplified design of fire exposed concrete beams and columns: an evaluation of Eurocode and Swedish building code against advanced computer models. Lund: Lund University, 2000.
RIGBERTH
J
Simplified design of fire exposed concrete beams and columns: an evaluation of Eurocode and Swedish building code against advanced computer models
Lund
Lund University
2000
RIVA, P.; FRANSSEN, J. M. Non-linear and plastic analysis of RC beams subjected to fire. Structural Concrete, v. 9, n. 1, p. 31-43, 2008.
RIVA
P
FRANSSEN
J. M
Non-linear and plastic analysis of RC beams subjected to fire
Structural Concrete
9
1
31
43
2008
SHI, X. et al. Influence of concrete cover on fire resistance of reinforced concrete flexural members. Journal of Structural Engineering, v. 130, n. 8, p. 1225-1232, 2004.
SHI
X
Influence of concrete cover on fire resistance of reinforced concrete flexural members
Journal of Structural Engineering
130
8
1225
1232
2004
Silva, A. R. D. Sistema computacional para análise avançada estática e dinâmica de estruturas metálicas. Ouro Preto, 2009. 322 f. Tese (Doutorado em Engenharia Civil) - Universidade Federal de Ouro Preto, Ouro Preto, 2009.
Silva
A. R. D
Sistema computacional para análise avançada estática e dinâmica de estruturas metálicas
Ouro Preto
2009
322 f
Tese (Doutorado em Engenharia Civil)
Universidade Federal de Ouro Preto
Ouro Preto
SILVA, V. P. Dimensionamento de vigas de concreto armado em situação de incêndio: aprimoramento de algumas recomendações do Eurocode. Revista Ibracon de Estruturas e Materiais, v. 4, n. 2, p. 277-303, 2011.
SILVA
V. P
Dimensionamento de vigas de concreto armado em situação de incêndio: aprimoramento de algumas recomendações do Eurocode
Revista Ibracon de Estruturas e Materiais
4
2
277
303
2011
SILVA, V. P. Projeto de estruturas de concreto em situação de incêndio: conforme ABNT NBR 15200:2012. São Paulo: Edgard Blücher, 2012.
SILVA
V. P
Projeto de estruturas de concreto em situação de incêndio: conforme ABNT NBR 15200:2012
São Paulo
Edgard Blücher
2012
SILVA, V. P. Segurança contra incêndio em edifícios: considerações para o projeto de arquitetura. São Paulo: Edgard Blücher, 2014.
SILVA
V. P
Segurança contra incêndio em edifícios: considerações para o projeto de arquitetura
São Paulo
Edgard Blücher
2014
ŠTEFAN, R.; PROCHÁZKA, J. Computer program for fire check of concrete members. In: INTERNATIONAL CONFERENCE APPLICATIONS OF STRUCTURAL FIRE ENGINEERING, Prague, 2009. Proceedings […] Prague: Czech Technical University, 2009.
ŠTEFAN
R.
PROCHÁZKA
J.
Computer program for fire check of concrete members
INTERNATIONAL CONFERENCE APPLICATIONS OF STRUCTURAL FIRE ENGINEERING
Prague
2009
Proceedings
Prague
Czech Technical University
2009
SUK, D. A.; FERRARI, V. Aplicação do concreto reforçado com fibras de aço (CRFA) em vigas submetidas ao cisalhamento. Ambiente Construído, Porto Alegre, v. 24, e129720, jan./dez. 2024.
SUK
D. A
FERRARI
V
Aplicação do concreto reforçado com fibras de aço (CRFA) em vigas submetidas ao cisalhamento
Ambiente Construído
Porto Alegre
24
e129720
129720
129720
jan./dez
2024
SUPORTE ALTOQI. Verificação em situação de incêndio no AltoQi Eberick. Disponível em: https://suporte.altoqi.com.br/hc/pt-br/articles/21661437075479. Acesso em: 5 out. 2023.
SUPORTE ALTOQI
Verificação em situação de incêndio no AltoQi Eberick
Disponível em: https://suporte.altoqi.com.br/hc/pt-br/articles/21661437075479
5 out. 2023
2023
Szép, J.; Rad, M. M.; Habashneh, M. Enhancing fire-resistant design of reinforced concrete beams by investigating the influence of reliability-based analysis. Engineering Reports, p. 1–15, 2024.
Szép
J
Rad
M. M
Habashneh
M
Enhancing fire-resistant design of reinforced concrete beams by investigating the influence of reliability-based analysis
Engineering Reports
1
15
2024
TQS INFORMÁTICA. Verificação em incêndio. Disponível em: https://www.tqs.com.br/v15/novidades/incendio.html. Acesso em: 5 out. 2023.
TQS INFORMÁTICA
Verificação em incêndio
Disponível em: https://www.tqs.com.br/v15/novidades/incendio.html
5 out. 2023
2023
Tutikian, B. F. et al. Análise das resistências ao escoamento (fy) e de ruptura (fu) residual das armaduras de pilares de concreto em altas temperaturas. Ambiente Construído, Porto Alegre, v. 21, n. 1, p. 51-67, jan./mar. 2021.
Tutikian
B. F.
Análise das resistências ao escoamento (fy) e de ruptura (fu) residual das armaduras de pilares de concreto em altas temperaturas
Ambiente Construído
Porto Alegre
21
1
51
67
jan./mar.
2021
VILLA, S. B.; BRUNO, D. C.; SANTOS, A. L. T. Avaliação pós-ocupação da qualidade na habitação por meio do aplicativo “Como você mora?”: estudo de caso na cidade de Uberlândia. Ambiente Construído, Porto Alegre, v. 20, n. 3, p. 225-247, jul./set. 2020.
VILLA
S. B
BRUNO
D. C
SANTOS
A. L. T
Avaliação pós-ocupação da qualidade na habitação por meio do aplicativo “Como você mora?”: estudo de caso na cidade de Uberlândia
Ambiente Construído
Porto Alegre
20
3
225
247
jul./set
2020
VITOR, P. C. P.; SANTOS, A. C.; TRAUTWEIN, L. M. Resistência ao cisalhamento em vigas de concreto armado sem armadura transversal reforçadas com fibras de aço. Ambiente Construído, Porto Alegre, v. 18, n. 3, p. 255-270, jul./set. 2018.
VITOR
P. C. P
SANTOS
A. C
TRAUTWEIN
L. M
Resistência ao cisalhamento em vigas de concreto armado sem armadura transversal reforçadas com fibras de aço
Ambiente Construído
Porto Alegre
18
3
255
270
jul./set
2018
WIT, A. Behaviour and structural design of concrete structures exposed to fire. Stockholm, 2011. 125 f. Thesis (Master of Science) - Royal Institute of Technology (KTH), Stockholm, 2011.
WIT
A
Behaviour and structural design of concrete structures exposed to fire
Stockholm
2011
125 f
Thesis (Master of Science)
Royal Institute of Technology (KTH)
Stockholm
WU, B.; LU, J. Z. A numerical study of the behaviour of restrained RC beams at elevated temperatures. Fire Safety Journal, v. 44, n. 4, p. 522-531, 2009.
WU
B
LU
J. Z
A numerical study of the behaviour of restrained RC beams at elevated temperatures
Fire Safety Journal
44
4
522
531
2009
ZHA, X. X. Three-dimensional non-linear analysis of reinforced concrete members in fire. Building and Environment, v. 38, n. 2 p. 297-307, 2003.
ZHA
X. X
Three-dimensional non-linear analysis of reinforced concrete members in fire
Building and Environment
38
2
297
307
2003
Authorship
Gabriela Bandeira de Melo Lins de Albuquerque Departamento de Engenharia de Estruturas e Geotécnica, Escola Politécnica | Universidade de São Paulo | Av. Prof. Almeida Prado, travessa 2, 83, Edifício da Engenharia Civil | São Paulo – SP – Brasil | CEP 05508900 | Tel.: (11) 3091-5367 |E-mail: gabriela.lins@usp.brDepartamento de Engenharia de Estruturas e Geotécnica, Escola Politécnica | Universidade de São Paulo | Tel.: (11) 3091-5562 | E-mail: valpigss@usp.br
Conceitualização
Curadoria de dados
Análise de dados
Pesquisa
Metodologia
Desenvolvimento, implementação e teste de software
Validação de dados
Design da apresentação de dados
Redação do manuscrito original
Redação - revisão e edição
Universidade de São Paulo. São Paulo - SP - BrasilUniversidade de São PauloBrasilSão Paulo, SP, BrasilUniversidade de São Paulo. São Paulo - SP - Brasil
Universidade de São Paulo. São Paulo - SP - BrasilUniversidade de São PauloBrasilSão Paulo, SP, BrasilUniversidade de São Paulo. São Paulo - SP - Brasil
Departamento de Engenharia de Estruturas e Geotécnica, Escola Politécnica | Universidade de São Paulo | Av. Prof. Almeida Prado, travessa 2, 83, Edifício da Engenharia Civil | São Paulo – SP – Brasil | CEP 05508900 | Tel.: (11) 3091-5367 |E-mail: gabriela.lins@usp.brDepartamento de Engenharia de Estruturas e Geotécnica, Escola Politécnica | Universidade de São Paulo | Tel.: (11) 3091-5562 | E-mail: valpigss@usp.br
Editores
Marcelo Henrique Farias de Medeiros e Eduardo Pereira
SCIMAGO INSTITUTIONS RANKINGS
Universidade de São Paulo. São Paulo - SP - BrasilUniversidade de São PauloBrasilSão Paulo, SP, BrasilUniversidade de São Paulo. São Paulo - SP - Brasil
Universidade de São Paulo. São Paulo - SP - BrasilUniversidade de São PauloBrasilSão Paulo, SP, BrasilUniversidade de São Paulo. São Paulo - SP - Brasil
Figura 3
Armaduras inseridas em modelo de viga para análises estruturais: uma camada positiva (a), duas camadas positivas (b), uma camada negativa (c) e duas camadas negativas (d)
Figura 7
Gráfico para dimensionamento de vigas de concreto armado com momentos positivos, concreto de resistência característica à compressão (fck) entre 25 e 50 MPa (classes C25 a C50), e aço de resistência à tração (fyk) igual a 500 MPa (classe CA-50)
Figura 12
Tela de resultados da calculadora TRFVIG: dados de entrada (painel esquerdo) e memorial de cálculo, com TRF da viga e gráfico µ vs TRF (painel direito)
Figura 14
Características das vigas adotadas nos exemplos de aplicação: modelo de viga simplesmente apoiada (a), esquema estático representativo de trecho de viga contínua com dois vãos simétricos (b), e seção transversal das vigas simplesmente apoiadas e contínuas (c)
Tabela 1
Propriedades do concreto em função das temperaturas adotadas nas análises térmicas, definidas conforme as equações propostas pela NBR 15200 (ABNT, 2012)
Tabela 3
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) de vigas simplesmente apoiadas, com comparações em relação à calculadora TRFVIG
imageFigura 1
Dimensões mínimas de largura (bmín) e distância entre o eixo da armadura longitudinal inferior e a face do concreto exposta ao fogo (c1)
open_in_new
imageFigura 3
Armaduras inseridas em modelo de viga para análises estruturais: uma camada positiva (a), duas camadas positivas (b), uma camada negativa (c) e duas camadas negativas (d)
open_in_new
imageFigura 7
Gráfico para dimensionamento de vigas de concreto armado com momentos positivos, concreto de resistência característica à compressão (fck) entre 25 e 50 MPa (classes C25 a C50), e aço de resistência à tração (fyk) igual a 500 MPa (classe CA-50)
open_in_new
imageFigura 8
Fluxograma do desenvolvimento da estrutura da calculadora TRFVIG
open_in_new
imageFigura 9
Exemplo de configuração de uma das tabelas inseridas no arquivo texto com o banco de dados da calculadora
open_in_new
imageFigura 10
Características das vigas que compõem o banco de dados da calculadora
open_in_new
imageFigura 11
Tela inicial da calculadora TRFVIG: dados de entrada (painel esquerdo) e considerações gerais (painel direito)
open_in_new
imageFigura 12
Tela de resultados da calculadora TRFVIG: dados de entrada (painel esquerdo) e memorial de cálculo, com TRF da viga e gráfico µ vs TRF (painel direito)
open_in_new
imageFigura 13
Fluxograma com procedimento de cálculo do programa de computador TRFVIG
open_in_new
imageFigura 14
Características das vigas adotadas nos exemplos de aplicação: modelo de viga simplesmente apoiada (a), esquema estático representativo de trecho de viga contínua com dois vãos simétricos (b), e seção transversal das vigas simplesmente apoiadas e contínuas (c)
open_in_new
imageFigura 15
Resultados calculadora TRFVIG vs método gráfico para vigas simplesmente apoiadas (a) e vigas contínuas a (b), b (c) e c (d)
open_in_new
imageFigura 16
Resultados calculadora TRFVIG vs método tabular para vigas simplesmente apoiadas (a) e vigas contínuas a (b), b (c) e c (d)
open_in_new
table_chartTabela 1
Propriedades do concreto em função das temperaturas adotadas nas análises térmicas, definidas conforme as equações propostas pela NBR 15200 (ABNT, 2012)
Temperatura do concreto (θc) [°C]
Condutividade térmica (λc,𝜃c) [W/(m °C)]
Temperatura do concreto (θc) [°C]
Calor específico (cp,𝜃c) [J/(kg °C)]
Temperatura do concreto (θc) [°C]
Massa específica (ρc,𝜃c) [kg/m3]
20
1,3330
20
900
20
2400,000
200
1,1108
100
900
100
2400,000
300
1,0033
100
1470
115
2400,000
400
0,9072
115
1470
116
2399,435
500
0,8225
200
1000
200
2352,000
600
0,7492
300
1050
300
2316,000
700
0,6873
400
1100
400
2280,000
800
0,6368
500
1100
500
2259,000
900
0,5977
1200
1100
1200
2112,000
1000
0,5700
-
-
-
-
1100
0,5537
-
-
-
-
1200
0,5488
-
-
-
-
table_chartTabela 2µ em função das características da seção da viga e TRF
1 camada positiva
Viga 14x40 (cobrimento = 2,5 cm / ϕt = 5 mm)
μ
ϕ [mm]
t [min]/ϕ
0
15
30
45
60
75
90
105
120
135
150
165
180
10
2ϕ10
1,0000
1,0000
1,0000
1,0000
0,7228
0,4479
0,2605
0,1804
0,1203
0,0955
0,0738
0,0634
0,0566
3ϕ10
1,0000
1,0000
1,0000
1,0000
0,8188
0,5458
0,3370
0,2236
0,1505
0,1114
0,0857
0,0714
0,0607
12,5
2ϕ12,5
1,0000
1,0000
1,0000
1,0000
0,7714
0,4857
0,2907
0,1966
0,1314
0,1014
0,0793
0,0656
0,0585
3ϕ12,5
1,0000
1,0000
1,0000
1,0000
0,8580
0,5804
0,3642
0,2418
0,1617
0,1187
0,0908
0,0741
0,0627
16
2ϕ16
1,0000
1,0000
1,0000
1,0000
0,8343
0,5449
0,3398
0,2199
0,1491
0,1100
0,0872
0,0690
0,0614
20
2ϕ20
1,0000
1,0000
1,0000
1,0000
0,9062
0,6168
0,3985
0,2509
0,1727
0,1201
0,0965
0,0758
0,0647
table_chartQuadro 1
Exemplos de vigas simplesmente apoiadas
Viga
pk [kN/m]
L [m]
bw [cm]
h [cm]
Dimensionamento à temperatura ambiente
Carregamento em incêndio
a
55
4
35
40
ϕt = 5 mm; c = 25 mm; As+ = 6ϕ16 mm (1 camada)
Biblioteca ψ2 = 0,6 pd,fi = 49 kN/m
b
20
4,5
25
45
ϕt = 5 mm; c = 40 mm; As+ = 6ϕ10 mm (1 camada)
Edifício residencial ψ2 = 0,3 pd,fi = 16 kN/m
c
30
5
14
50
ϕt = 5 mm; c = 30 mm; As+ = 4ϕ16 mm (2 camadas)
Escritório ψ2 = 0,4 pd,fi = 25 kN/m
d
20
6
19
60
ϕt = 5 mm; c = 25 mm; As+ = 3ϕ16 mm (1 camada)
Edifício residencial ψ2 = 0,3 pd,fi = 16 kN/m
table_chartQuadro 2
Exemplos de vigas contínuas
Viga
pk [kN/m]
L [m]
bw [cm]
h [cm]
Dimensionamento à temperatura ambiente
Carregamento em incêndio
Sem redistribuição
Com redistribuição
a
55
5,5
35
55
As+ = 4ϕ16 mm (1 camada) As- = 8ϕ16 mm (1 camada)
As+ = 8ϕ12,5 mm (1 camada) As- = 4ϕ20 mm (1 camada)
Biblioteca ψ2 = 0,6 pd,fi = 49 kN/m
ϕt = 6,3 mm; c = 30 mm
b
20
6
19
60
As+ = 4ϕ10 mm (1 camada) As- = 3ϕ16 mm (1 camada)
As+ = 3ϕ12,5 mm (1 camada) As- = 4ϕ12,5 mm (1 camada)
Edifício residencial ψ2 = 0,3 pd,fi = 16 kN/m
ϕt = 5 mm; c = 25 mm
c
40
7
30
70
As+ = 6ϕ12,5 mm (1 camada) As- = 12ϕ12,5 mm (2 camadas)
As+ = 12ϕ10 mm (2 camadas) As- = 8ϕ12,5 mm (2 camadas)
Arquibancada ψ2 = 0,4 pd,fi = 33 kN/m
ϕt = 5 mm; c = 40 mm
table_chartQuadro 3
Combinações de redistribuição de momentos em vigas contínuas
Casos de estudo
Redistribuição de momentos
Temperatura ambiente
Situação de incêndio
1
2
3
4
table_chartTabela 3
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) de vigas simplesmente apoiadas, com comparações em relação à calculadora TRFVIG
Resultados
Viga a
Viga b
Viga c
Viga d
Calculadora TRFVIG (x) [min]
130
121
98
98
Método gráfico (y) [min]
115
120
90
90
Diferença x - y [min]
15
1
8
8
Desvio padrão s [min]
7,5
0,5
4
4
Relação y/x [adimensional]
0,885
0,992
0,918
0,918
Erro [%]
-11,5
-0,8
-8,2
-8,2
Método tabular - Resultado 1 (z) [min]
90
96
64,5
66,5
Diferença x - z [min]
40
25
33,5
31,5
Desvio padrão s [min]
20
12,5
16,75
15,75
Relação z/x [adimensional]
0,692
0,793
0,658
0,679
Erro [%]
-30,8
-20,7
-34,2
-32,1
Método tabular - Resultado 2 (w) [min]
-
82,5
-
56
Diferença x - w [min]
-
38,5
-
42
Desvio padrão s [min]
-
19,25
-
21
Relação w/x [adimensional]
-
0,682
-
0,571
Erro [%]
-
-31,8
-
-42,9
table_chartTabela 4
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) da viga contínua a, com comparações em relação à calculadora TRFVIG
Resultados
Caso 1
Caso 2
Caso 3
Caso 4
Calculadora TRFVIG (x) [min]
130
147
157
154
Método gráfico (y) [min]
125
145
150
140
x - y [min]
5
2
7
14
Desvio padrão s [min]
2,5
1
3,5
7
Relação y/x [adimensional]
0,962
0,986
0,955
0,909
Erro [%]
-3,8
-1,4
-4,5
-9,1
Método tabular - Resultado 1 (z) [min]
150
150
150
150
x - z [min]
-20
-3
7
4
Desvio padrão s [min]
10
1,5
3,5
2
Relação z/x [adimensional]
1,154
1,020
0,955
0,974
Erro [%]
15,4
2
-4,5
-2,6
Método tabular - Resultado 2 (w) [min]
117,5
112,5
117,5
112,5
x - w [min]
12,5
34,5
39,5
41,5
Desvio padrão s [min]
6,25
17,25
19,75
20,75
Relação w/x [adimensional]
0,904
0,765
0,748
0,731
Erro [%]
-9,6
-23,5
-25,2
-26,9
table_chartTabela 5
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) da viga contínua b, com comparações em relação à calculadora TRFVIG
Resultados
Caso 1
Caso 2
Caso 3
Caso 4
Calculadora TRFVIG (x) [min]
90
109
104
98
Método gráfico (y) [min]
85
105
100
95
x - y [min]
5
4
4
3
Desvio padrão s [min]
2,5
2
2
1,5
Relação y/x [adimensional]
0,944
0,963
0,962
0,969
Erro [%]
-5,6
-3,7
-3,8
-3,1
Calculadora TRFVIG (x) [min]
90
109
104
98
Método tabular - Resultado 1 (z) [min]
86
88
86
88
x - z [min]
4
21
18
10
Desvio padrão s [min]
2
10,5
9
5
Relação z/x [adimensional]
0,956
0,807
0,827
0,898
Erro [%]
-4,4
-19,3
-17,3
-10,2
Calculadora TRFVIG (x) [min]
90
109
104
98
Método tabular - Resultado 2 (w) [min]
75,5
78,5
75,5
78,5
x - w [min]
14,5
30,5
28,5
19,5
Desvio padrão s [min]
7,25
15,25
14,25
9,75
Relação w/x [adimensional]
0,839
0,720
0,726
0,801
Erro [%]
-16,1
-28
-27,4
-19,9
table_chartTabela 6
Análise estatística dos resultados de tempo de resistência ao fogo (TRF) da viga contínua c, com comparações em relação à calculadora TRFVIG